Expostats

Free Bayesian tool that turns your workplace air measurements, non detects included, into the chance that a group of workers is overexposed.

Guidance Tier 3 (measurement based) Complete Last reviewed 28 November 2026

Quick answer

You have air measurements for a group of workers who do similar work and you want to know whether they are below the limit value. Expostats Tool1 gives the chance that the group is overexposed, the level 95 out of 100 shifts stay below, and the share of shifts above the limit, each with its uncertainty. It handles results below the detection limit properly. It does not estimate exposure from a safety data sheet: you need measurements.

What it is

A free set of web tools from the Université de Montréal, developed in the WebExpo project funded by the Québec institute IRSST and published in 2019. Tool1 interprets the results of one similar exposure group. It assumes the results follow a lognormal distribution, as workplace air measurements usually do, and uses Bayesian statistics, so the answer is a probability that you can act on. The code is public.

Does it apply to you?

Use it for Do not use it for
Full shift (or short term) air measurements of workers with similar exposure Estimating exposure before you have measured
Small data sets, from a few results on Comparing individual workers or groups (other Expostats tools)
Results below the detection limit, or reported as a range Results that clearly do not fit one group

How it works

  1. Enter the results and the limit value in the same unit. A result below the detection limit is entered as “below” that limit.
  2. Model. Expostats fits a lognormal distribution to the results. A built in prior on the spread between shifts helps when there are few results.
  3. Estimates. You get the geometric mean, the geometric standard deviation, the 95th percentile, the share of shifts above the limit (exceedance fraction) and the average, each with a 90% interval.
  4. Verdict. Overexposure means the 95th percentile is at or above the limit. If the chance of that is 30% or more, the situation is problematic; below 30% it is acceptable. You can also judge on the share of shifts above the limit or on the average.

What you need from your safety data sheets

Input Where
Limit value (8 hour or short term) Section 8.1, or your national limit list
Measurement results Your own measurement reports, not the SDS

What NextSDS does with it

NextSDS implemented Expostats Tool1 with the same model, priors and settings, and checked it against the Tool1 code itself: the results agree within simulation noise. You can try it below. The result also shows the EN 689 compliance test on the same data. It is not yet part of the NextSDS product.

Countries

CountryRoleBasis
CanadaOwnerDeveloped at Université de Montréal with IRSST funding (WebExpo project 2014-0073); Lavoué et al. 2019, Ann Work Expo Health 63(3):267 to 279

Used internationally by occupational hygienists; no country makes it mandatory.

Limitations

  • You need measurements of one group of workers with similar exposure.
  • With very few results, the answer leans on the built in assumption about the spread between shifts.
  • When every result is below the detection limit, the estimates are uncertain.
  • It assumes a lognormal distribution; check that your results fit one group.

Key dates

  1. Tool1 version 5.2.0.
  2. Reference paper in the Annals of Work Exposures and Health.

Frequently asked questions

How many measurements do I need?

Expostats gives an answer from a few results, with a wide interval. More results narrow the interval and make the verdict firmer.

What do I do with results below the detection limit?

Enter them as below the limit of detection. Expostats uses them as censored values; you do not replace them by half the detection limit.

Is this the same as the EN 689 test?

No, but it asks a similar question: is the 95th percentile below the limit with enough certainty? EN 689 uses a fixed statistical test; Expostats gives the probability.

  • ART: a model estimate that can be updated with measurements.

Official sources

This page is not legal advice; always check the official text.

Key facts

Expostats

Scope

Type
Guidance
Tier
3 (measurement based)
Routes
Inhalation
Populations
Workers
Exposure forms
Vapour, gas, dust, mist, fume, fibres

Status

Legal status
No formal status; free practitioner tool
Current version
Tool1 5.2.0
Version date
18 July 2025
Licence type
Open licence
Licence terms
Free web tool; code MIT and Apache 2.0

Source

Official name
Expostats: A Bayesian Toolkit to Aid the Interpretation of Occupational Exposure Measurements
Owner
Jérôme Lavoué, Université de Montréal (Canada); WebExpo project funded by IRSST
Official site
expostats.ca

Try it

Calculate Expostats with your own inputs

Loading the calculation...

NextSDS

2,437 SDSs. None left to chase.

NextSDS collects the safety data sheets you receive and keeps them current, so the inputs for Expostats and every other framework on this site are at hand.