Advanced REACH Tool (ART)

A higher tier web tool that estimates the full shift inhalation exposure of workers to vapours, mists and dusts in mg/m3, for when a screening tool shows a possible risk.

Exposure model Tier 2 (refined) Complete Last reviewed 28 November 2026

Quick answer

ART estimates how much of a vapour, mist or dust a worker breathes in over a shift, in mg/m3. Use it when a screening tool such as ECETOC TRA or the EMKG-Expo-Tool shows a possible risk and you can describe the task in detail. Do not use it for gases, fumes, fibres or skin exposure.

What it is

ART is a free web tool built by a European consortium of six research institutes: TNO and IRAS (Netherlands), BAuA (Germany), NFA/NRCWE (Denmark), and IOM and HSL (United Kingdom). TNO hosts it. Version 1.0 came out in 2010 and version 1.5 in 2013. ECHA names ART as a higher tier (Tier 2) tool for worker exposure under REACH.

ART has two parts:

  1. A model that scores each task from the product, the activity, the controls and the room, and converts the score to mg/m3 using a calibration on measured data.
  2. An optional statistical step that combines this estimate with your own measurements, or with measurements from similar situations in the ART library.

Does it apply to you?

ART fits you when:

  • Your workers handle liquids or powders indoors or outdoors and may breathe in vapour, mist or dust.
  • A screening assessment gave a risk ratio above 1 and you want a more realistic estimate before adding controls.
  • You can describe the task: activity, amounts, local exhaust, room size, ventilation and duration.

ART does not fit when:

  • The exposure is a gas, a fume (for example welding or hot metal), a fibre or a reaction product such as exhaust.
  • You need skin exposure: ART covers inhalation only. See dART for the dermal model in development.
  • You work with nanomaterials.
  • You want to take credit for respirators: ART does not include them.

How it works

  1. Describe the shift. Up to four activities plus time without exposure, together about 8 hours.
  2. Substance. ART scores how easily the product releases into the air: vapour pressure and mole fraction for vapours, dustiness and moisture for powders, viscosity for mists, always corrected for the concentration in the product.
  3. Activity. You choose the activity class (for example spraying, pouring, mixing, handling contaminated objects) and answer the questions for that class, such as scale and direction.
  4. Controls and room. Local controls (from none to a glove box), segregation, a separate control room, housekeeping, room volume and air changes per hour, or outdoors.
  5. Near and far field. ART adds the source near the worker’s head and sources further away, then averages over the shift.
  6. Result. The score is converted to mg/m3 and shown as a distribution with percentiles. For REACH the 90th percentile of the full shift distribution is the usual value.
  7. Optional update with measurements. You can add measured data for the same or a similar situation to sharpen the estimate.

What you need from your safety data sheets

Input Where on the SDS
Product type (liquid, powder, paste, solid object) Section 9 (physical state), section 1.2 (identified use)
Concentration of the substance in the product Section 3
Vapour pressure or boiling point Section 9
Viscosity (for mists) Section 9
Dustiness and moisture (for powders) Section 9, rarely given
Engineering controls and ventilation Section 8.2
Exposure limit to compare the result with Section 8.1

Task details (activity, duration, room size, process temperature) are not on the SDS. You add them from the workplace.

What NextSDS does with it

NextSDS does not run ART yet. Today NextSDS screens worker inhalation exposure with Tier 1 tools (ECETOC TRA worker and the EMKG-Expo-Tool). A higher tier inhalation estimate based on the published ART method is planned for products where screening shows a possible risk. Until then, use the ART web tool itself for those cases.

Countries

CountryRoleBasis
NetherlandsOwnerART credits page: TNO and IRAS (Utrecht University) in the consortium; tool hosted by TNO; Dutch Government co-funder
United KingdomOwnerART credits page: IOM and HSL in the consortium; registration page: software developed by HSL, Crown Copyright Health and Safety Executive
GermanyOwnerART credits page: BAuA in the consortium
DenmarkOwnerART credits page: NFA/NRCWE in the consortium
European UnionAcceptedECHA Guidance R.14 v2.1 (2012) section R.14.5.3: named Tier 2 tool for occupational exposure in REACH chemical safety reports
SwitzerlandUsedRuns in the TREXMO web tool (Unisante, supported by SECO)

Limitations

  • It needs a lot of detail and expert judgement in choosing inputs (ECHA R.14 v2.1).
  • No skin exposure, gases, fumes, fibres or reaction products.
  • Respirators are not taken into account.
  • The calibration is broad: the estimated geometric mean lies within a factor 2 to 6 of the measured one (Schinkel et al. 2011).
  • Independent studies found that ART can underestimate volatile liquids and overestimate powders, depending on the situation (Lee et al. 2019; Savic et al. 2020). Measurements remain the reference.
  • One substance per assessment.

Key dates

Date Event
June 2010 ART 1.0 released
November 2012 ECHA Guidance R.14 v2.1 names ART as a Tier 2 tool
18 January 2013 ART 1.5 released, with a library of measured scenarios
November 2026 ART 1.5 is still the current version on the website

Frequently asked questions

Is ART mandatory under REACH?

No. REACH allows any appropriate model. ART is one of the higher tier tools ECHA names in Guidance R.14.

Which result should I compare with the exposure limit?

ECHA R.14 v2.1 and the ART User Guide describe the 90th percentile of the full shift distribution for REACH.

Can I use ART for welding fume?

No. Fumes are outside the range ART was calibrated for.

Does ART take respirators into account?

No. The estimate is the concentration in the air without respiratory protection.

Does ART cost anything?

No. The web tool is free after registration.

Official sources

This page is not legal advice; always check the official text.

Key facts

ART

Scope

Type
Exposure model
Tier
2 (higher tier)
Routes
Inhalation
Populations
Workers
Exposure forms
Vapour, mist, dust

Status

Legal status
Named Tier 2 tool for occupational exposure in ECHA Guidance R.14 (v2.1, 2012)
Current version
1.5
Version date
18 January 2013
Licence type
Proprietary
Licence terms
Web tool free after registration; software Crown Copyright HSE

Source

Official name
Advanced REACH Tool (ART)
Owner
ART consortium (TNO, IRAS Utrecht University, BAuA, NFA/NRCWE, IOM, HSL); hosted by TNO

Try it

Calculate ART with your own inputs

Loading the calculation...

NextSDS

2,437 SDSs. None left to chase.

NextSDS collects the safety data sheets you receive and keeps them current, so the inputs for ART and every other framework on this site are at hand.

Try NextSDS How it works