ECETOC TRA worker is a free screening tool that estimates how much of a substance a worker breathes in and gets on the skin during a task. It gives one conservative number per task and compares it with the DNEL or occupational exposure limit as a risk characterisation ratio (RCR). Use it for vapours from liquids and dusts from powders; if the RCR is above 1, refine with a higher tier model or measurements. Do not use it for gases, sprays (mists), fumes or fibres.
What it is
The Targeted Risk Assessment (TRA) is published by ECETOC, a scientific association funded by the chemical industry in Brussels. The first version appeared in 2004. Version 2 (2009) adopted the REACH process categories (PROCs), version 3 (2012) added ventilation, skin modifiers and a clear applicability domain, and worker version 3.2 followed in October 2023. The worker part is a modified version of the EASE model of the UK Health and Safety Executive (ECHA Guidance R.14 v2.1). It comes as a standalone Excel workbook and as part of the Integrated TRA, which also covers consumers and the environment. ECHA built the TRA worker estimates into Chesar, its tool for REACH chemical safety reports.
Does it apply to you?
TRA worker fits when:
- you assess workers in industrial or professional settings;
- the substance is a liquid that evaporates (vapour) or a solid that can form dust;
- the task can be described by a REACH process category (PROC 1 to 25);
- you need a first, conservative screen, for example to check an exposure scenario or to decide which tasks need a closer look.
It does not fit for gases, aerosol mists from spraying, process fumes, fibres, solids dissolved or suspended in liquids, or molten non-mineral solids (ECETOC TR 114 Table 3). For metals and minerals, MEASE fits better for several PROCs. When the screen shows a possible risk, a higher tier model such as ART or Stoffenmanager gives a more realistic estimate.
How it works
- Pick the task and conditions. PROC, industrial or professional setting, physical state, and the volatility band (from the vapour pressure at the working temperature) or dustiness band.
- Look up the initial estimate. A fixed table gives a starting value per PROC, state, band, setting and local exhaust ventilation (LEV): in ppm for liquids, in mg/m3 for solids.
- Apply modifiers. The estimate is multiplied by factors for general ventilation (basic 1, good 0.7, outdoors 0.7, enhanced 0.3), task duration, concentration of the substance in the product (four bands from above 25% to below 1%) and respiratory protection (none, 90% or 95%) (TR 114 Table 1; TR 107 Table 2).
- Short term value. The 15 minute estimate is derived from the 8 hour value with a fixed multiplier (TR 114 section 2.2.2).
- Skin. A starting value per PROC and setting is adjusted for duration, concentration, gloves and LEV, giving mg/kg body weight per day and a local value in micrograms per cm2.
- Risk. Each estimate is divided by its reference value (DNEL or OEL). An RCR of 1 or less means the use is shown safe at this tier.
ECETOC describes the estimate as the 75th percentile of the 8 hour exposure distribution (TR 114 section 2.2.2).
What you need from your safety data sheets
| Input | Where on the SDS |
|---|---|
| Physical state (liquid or solid) | Section 9 |
| Vapour pressure (liquids) | Section 9 |
| Dustiness (solids) | Section 9, often missing |
| Molecular weight (to convert ppm to mg/m3) | Section 9 or section 3 |
| Concentration of each hazardous substance | Section 3 |
| Process categories and setting | Section 1.2 and the exposure scenario annex |
| LEV, respiratory protection, gloves | Section 8.2 and your own task data |
| Reference values (OEL, DNEL) | Section 8.1 and the exposure scenario |
Ventilation and task duration usually come from your own workplace, not from the SDS.
What NextSDS does with it
NextSDS has implemented TRA worker version 3.2. It runs the tool for each hazardous component of a product and each task, using the composition, physical data and limits from the SDS, and returns the 8 hour, short term and skin estimates with their RCRs. On 600 test cases the results, statuses and remarks equal the original ECETOC workbook. The tool’s own warnings are passed on, for example that aerosol exposure is not covered for spraying tasks. Keep in mind that TRA only predicts the vapour phase, so results for non-volatile components in sprays need expert judgement.
Countries
| Country | Role | Basis |
|---|---|---|
| Owner | ECETOC AISBL, Brussels, publishes the tool and Technical Reports TR 93, 107, 114, 124, 131 | |
| Accepted | ECHA Guidance R.14 v2.1 (2012) section R.14.4.8: the preferred Tier 1 tool; worker TRA embedded in ECHA Chesar (TR 114 section 1.2; TR 131); REACH Annex I 5.2.5 allows models; also applies in the EEA |
Limitations
- Liquids are assessed as vapour only; mists from spraying are not covered (TR 114 Table 3).
- The amount of product used is not an input (ECHA Guidance R.14 v2.1).
- The effect of LEV on skin exposure may be overestimated (ECHA Guidance R.14 v2.1).
- Concentration bands stop at “below 1%”, so stronger dilution does not lower the estimate further.
- Non-volatile ingredients can get high, unrealistic RCRs from the default values for very low volatility.
- PROC 26 and PROC 28 are not in the version 3.2 table.
- A study comparing TRA with measurements (ETEAM) found low conservatism for some tasks; ECETOC disputes parts of the method (TR 131 section 2.3).
Key dates
- Worker version 3.2 released.
- Technical Report 131 explains the technical basis of version 3.1.
- Version 3.1 (Technical Report 124).
- Version 3 (Technical Report 114).
- Version 2 aligned with REACH process categories (Technical Report 107).
- First Targeted Risk Assessment (Technical Report 93).
Frequently asked questions
Is the TRA result a worst case?
It is meant as a reasonable worst case. ECETOC describes it as the 75th percentile of the 8 hour exposure distribution, so real exposure is usually lower.
Can I use TRA worker for a spray product?
Only for the vapour of the substance. For spraying tasks the tool warns that aerosol exposure is not taken into account, so use a model that covers mists.
Does TRA take the quantity I use into account?
No. The amount used is not an input; the tool works with the task type, volatility or dustiness, concentration and controls.
Is the Chesar result the same as TRA?
Almost. Chesar uses the TRA worker engine, with minor differences such as a default operating temperature of 40 C (TR 131 Table 5).
What if my RCR is above 1?
The use is not shown safe at Tier 1. Check your inputs, add or improve controls, or refine with a higher tier model or measurements.
Related frameworks
- ECETOC TRA consumer: the consumer module of the same tool.
- ECETOC TRA environment: releases to the environment for the same exposure scenario.
- Chesar: ECHA’s chemical safety report tool, which uses the TRA worker engine.
- ART: higher tier inhalation model to refine a TRA screen.
- Stoffenmanager: higher tier inhalation model and control banding.
- MEASE: Tier 1 tool for metals and inorganic substances.
- EMKG-Expo-Tool: another Tier 1 worker tool named in ECHA guidance.
Official sources
- ECETOC Targeted Risk Assessment (TRA), ECETOC, official tool page, worker version 3.2, October 2023
- ECETOC Technical Report No. 93, Targeted Risk Assessment, December 2004
- ECETOC Technical Report No. 107, Addendum to ECETOC Targeted Risk Assessment Report No. 93, December 2009
- ECETOC Technical Report No. 114, ECETOC TRA version 3: Background and Rationale for the Improvements, July 2012
- ECETOC Technical Report No. 124, Addendum to TR114: Technical Basis for the TRA v3.1, June 2014
- ECETOC Technical Report No. 131, Targeted Risk Assessment: Further Explanation of the Technical Basis of the TRA v3.1, February 2018
- Guidance on information requirements and chemical safety assessment, Chapter R.14: Occupational exposure assessment, ECHA
- Regulation (EC) No 1907/2006 (REACH), Annex I, European Union