Quick answer
The EMKG-Expo-Tool gives an estimated range for the concentration of a substance in the air during a task, in mg/m3 for dust or ppm for vapour. You compare the upper end of the range with the DNEL or exposure limit. ECHA accepts it as a Tier 1 (screening) tool for REACH worker assessments, but it is not suited for gases, fumes, CMR substances or skin exposure.
What it is
The EMKG-Expo-Tool is a tool from the German Federal Institute for Occupational Safety and Health (BAuA). It was developed to help small and medium sized companies comply with the Chemical Agents Directive. It uses the banding approach of the British COSHH Essentials, but turns the result into a number: one of six exposure ranges, each one order of magnitude wide. ECHA describes it in its guidance on occupational exposure estimation (R.14) as an approach to filter situations without risk from those that need detailed attention. It is the exposure part of the German EMKG scheme.
Does it apply to you?
It fits companies and REACH registrants who need a quick, conservative estimate of inhalation exposure to compare with a DNEL or exposure limit.
| Use it for | Do not use it for |
|---|---|
| Vapour from liquids and dust from solids, breathed in | Gases, handled or released |
| Single tasks, or a full shift when the task lasts the whole shift | Fumes and dusts formed by the task, such as abrasive work |
| Comparison with a DNEL or exposure limit | CMR substances (carcinogens, mutagens, reproductive toxicants) |
| Skin exposure |
When the result is close to the limit, a higher tier tool such as Stoffenmanager or ART, or measurements, give a more precise answer.
How it works
- Dustiness (solids). High (fine light powder that stays airborne for minutes, such as cement or toner), medium (crystalline or granular, settles quickly, such as sugar) or low (pellets, waxes). In doubt, take the higher band.
- Volatility (liquids). From the boiling point at room temperature: low above 150 °C, medium 50 to 150 °C, high below 50 °C. At a higher working temperature, or from the vapour pressure: low below 0.5 kPa, medium 0.5 to 25 kPa, high above 25 kPa.
- Scale of use. Small (up to 1 kg or 1 litre), medium (1 to 1000 kg or litres) or large (more than 1 tonne or 1 m3) per batch. Using more than 1 litre a day spread over a large surface (more than 1 m2) moves the result one range up.
- Exposure potential. Amount and band give exposure potential 1 to 4.
- Control strategy. 1 general ventilation, 2 engineering control (local exhaust ventilation, partial enclosure), 3 containment.
- Exposure range. A table gives the range for each exposure potential and control strategy. For example, a medium amount of a medium volatile liquid with general ventilation gives 50 to 500 ppm.
- Short tasks. For less than 15 minutes a day, the next lower range can be used.
| Result | Meaning |
|---|---|
| Exposure range | Lower and upper value, in mg/m3 (dust) or ppm (vapour) |
| Upper value | Compare with the DNEL or exposure limit |
| Not recommended | General ventilation is not enough for the highest exposure potential |
What you need from your safety data sheets
| Input | Where on the SDS |
|---|---|
| Physical state (solid or liquid) | Section 9 |
| Boiling point or vapour pressure | Section 9 |
| Particle form or dustiness, if given | Section 9 |
| DNEL or exposure limit to compare with | Section 8 |
| Classification, to check for CMR properties | Sections 2 and 3 |
| Molecular weight, to convert ppm to mg/m3 | Section 9, if given |
| Amount, duration and control in place | Not on the SDS: from your workplace |
What NextSDS does with it
| Check | SDS data used | What it tells you |
|---|---|---|
| Risk assessment | Sections 2, 3 and 9, quantities per workplace | EMKG exposure range per task, with the wide dispersive use and short task rules |
| Exposure limits | Section 3 against the national limit list | The limit to compare the upper value with |
| CMR and vulnerable groups | Sections 2 and 3 | Products with carcinogens, mutagens or reproductive toxicants, outside the tool’s scope |
| Exposure and PPE | Section 8 | Exposure routes, EMKG exposure class and PPE per body part |
NextSDS follows the method as published by ECHA. It adds one step: it converts ppm to mg/m3 with the molecular weight, so you can compare vapour results with limits in mg/m3.
Countries
| Country | Role | Basis |
|---|---|---|
| Owner | BAuA tool; ECHA R.14 v2.1 §R.14.4.9: 'the German EMKG-Expo-Tool' (BAuA 2008) | |
| Accepted | ECHA Guidance R.14 v2.1 (Nov 2012) §R.14.4.9: Tier 1 tool for REACH chemical safety assessment, 'sufficiently conservative for a Tier 1 tool and can thus be used as such' |
Limitations
- Inhalation only; no skin exposure.
- The substance is assumed to be at 100% in the product, so dilution is not reflected.
- The method has no rule for water based solutions, so water based products are banded on the boiling point of water.
- Few input choices, and the calculation steps are not visible to the user.
- Validation (cited by ECHA): solids and medium scale use of liquids were lower than or within the range, while wide dispersive use of small amounts of solvent based products sometimes exceeded the range.
Key dates
| Date | Event |
|---|---|
| November 2012 | ECHA Guidance R.14 version 2.1 describes the tool |
| May 2010 | ECHA Guidance R.14 version 2 revises the text on the tool |
| 2008 | EMKG-Expo-Tool published by BAuA |
Frequently asked questions
Can I use the EMKG-Expo-Tool for REACH?
Yes. ECHA Guidance R.14 describes it as a Tier 1 tool. Use the upper end of the range to calculate the risk characterisation ratio.
Why are liquid results in ppm?
ECHA gives the vapour ranges in ppm. Convert them with the molecular weight to compare with a DNEL or limit in mg/m3.
Can I use it for a carcinogen or other CMR substance?
No. ECHA states that the tool is not suitable for CMR substances.
Which SDS data do I need?
The physical state and the boiling point or vapour pressure in section 9, and the DNEL or exposure limit in section 8 to compare with.
Related frameworks
- EMKG: BAuA’s control banding scheme that the tool belongs to.
- COSHH Essentials: uses the same exposure matrix, without numbers.
- ILO International Chemical Control Toolkit: international version of the banding approach.
- ECETOC TRA worker: another Tier 1 worker tool described in ECHA Guidance R.14.
- Stoffenmanager and ART: higher tier exposure tools.
Official sources
- EMKG-Expo-Tool 2, BAuA
- Guidance on information requirements and chemical safety assessment, ECHA, Chapter R.14 Occupational exposure assessment
Based on research of 28 November 2026. This page is not legal advice; always check the official text.