EMKG-Expo-Tool

BAuA Tier 1 tool that estimates an inhalation exposure range from the volatility or dustiness, amount and control in place, to compare with a DNEL or exposure limit.

Exposure model Tier 1 (screening) Complete Last reviewed 28 November 2026

Quick answer

The EMKG-Expo-Tool gives an estimated range for the concentration of a substance in the air during a task, in mg/m3 for dust or ppm for vapour. You compare the upper end of the range with the DNEL or exposure limit. ECHA accepts it as a Tier 1 (screening) tool for REACH worker assessments, but it is not suited for gases, fumes, CMR substances or skin exposure.

What it is

The EMKG-Expo-Tool is a tool from the German Federal Institute for Occupational Safety and Health (BAuA). It was developed to help small and medium sized companies comply with the Chemical Agents Directive. It uses the banding approach of the British COSHH Essentials, but turns the result into a number: one of six exposure ranges, each one order of magnitude wide. ECHA describes it in its guidance on occupational exposure estimation (R.14) as an approach to filter situations without risk from those that need detailed attention. It is the exposure part of the German EMKG scheme.

Does it apply to you?

It fits companies and REACH registrants who need a quick, conservative estimate of inhalation exposure to compare with a DNEL or exposure limit.

Use it for Do not use it for
Vapour from liquids and dust from solids, breathed in Gases, handled or released
Single tasks, or a full shift when the task lasts the whole shift Fumes and dusts formed by the task, such as abrasive work
Comparison with a DNEL or exposure limit CMR substances (carcinogens, mutagens, reproductive toxicants)
Skin exposure

When the result is close to the limit, a higher tier tool such as Stoffenmanager or ART, or measurements, give a more precise answer.

How it works

  1. Dustiness (solids). High (fine light powder that stays airborne for minutes, such as cement or toner), medium (crystalline or granular, settles quickly, such as sugar) or low (pellets, waxes). In doubt, take the higher band.
  2. Volatility (liquids). From the boiling point at room temperature: low above 150 °C, medium 50 to 150 °C, high below 50 °C. At a higher working temperature, or from the vapour pressure: low below 0.5 kPa, medium 0.5 to 25 kPa, high above 25 kPa.
  3. Scale of use. Small (up to 1 kg or 1 litre), medium (1 to 1000 kg or litres) or large (more than 1 tonne or 1 m3) per batch. Using more than 1 litre a day spread over a large surface (more than 1 m2) moves the result one range up.
  4. Exposure potential. Amount and band give exposure potential 1 to 4.
  5. Control strategy. 1 general ventilation, 2 engineering control (local exhaust ventilation, partial enclosure), 3 containment.
  6. Exposure range. A table gives the range for each exposure potential and control strategy. For example, a medium amount of a medium volatile liquid with general ventilation gives 50 to 500 ppm.
  7. Short tasks. For less than 15 minutes a day, the next lower range can be used.
Result Meaning
Exposure range Lower and upper value, in mg/m3 (dust) or ppm (vapour)
Upper value Compare with the DNEL or exposure limit
Not recommended General ventilation is not enough for the highest exposure potential

What you need from your safety data sheets

Input Where on the SDS
Physical state (solid or liquid) Section 9
Boiling point or vapour pressure Section 9
Particle form or dustiness, if given Section 9
DNEL or exposure limit to compare with Section 8
Classification, to check for CMR properties Sections 2 and 3
Molecular weight, to convert ppm to mg/m3 Section 9, if given
Amount, duration and control in place Not on the SDS: from your workplace

What NextSDS does with it

Check SDS data used What it tells you
Risk assessment Sections 2, 3 and 9, quantities per workplace EMKG exposure range per task, with the wide dispersive use and short task rules
Exposure limits Section 3 against the national limit list The limit to compare the upper value with
CMR and vulnerable groups Sections 2 and 3 Products with carcinogens, mutagens or reproductive toxicants, outside the tool’s scope
Exposure and PPE Section 8 Exposure routes, EMKG exposure class and PPE per body part

NextSDS follows the method as published by ECHA. It adds one step: it converts ppm to mg/m3 with the molecular weight, so you can compare vapour results with limits in mg/m3.

Countries

CountryRoleBasis
GermanyOwnerBAuA tool; ECHA R.14 v2.1 §R.14.4.9: 'the German EMKG-Expo-Tool' (BAuA 2008)
European UnionAcceptedECHA Guidance R.14 v2.1 (Nov 2012) §R.14.4.9: Tier 1 tool for REACH chemical safety assessment, 'sufficiently conservative for a Tier 1 tool and can thus be used as such'

Limitations

  • Inhalation only; no skin exposure.
  • The substance is assumed to be at 100% in the product, so dilution is not reflected.
  • The method has no rule for water based solutions, so water based products are banded on the boiling point of water.
  • Few input choices, and the calculation steps are not visible to the user.
  • Validation (cited by ECHA): solids and medium scale use of liquids were lower than or within the range, while wide dispersive use of small amounts of solvent based products sometimes exceeded the range.

Key dates

Date Event
November 2012 ECHA Guidance R.14 version 2.1 describes the tool
May 2010 ECHA Guidance R.14 version 2 revises the text on the tool
2008 EMKG-Expo-Tool published by BAuA

Frequently asked questions

Can I use the EMKG-Expo-Tool for REACH?

Yes. ECHA Guidance R.14 describes it as a Tier 1 tool. Use the upper end of the range to calculate the risk characterisation ratio.

Why are liquid results in ppm?

ECHA gives the vapour ranges in ppm. Convert them with the molecular weight to compare with a DNEL or limit in mg/m3.

Can I use it for a carcinogen or other CMR substance?

No. ECHA states that the tool is not suitable for CMR substances.

Which SDS data do I need?

The physical state and the boiling point or vapour pressure in section 9, and the DNEL or exposure limit in section 8 to compare with.

Official sources

Based on research of 28 November 2026. This page is not legal advice; always check the official text.

Key facts

EMKG-Expo-Tool

Scope

Type
Exposure model
Tier
1 (screening)
Routes
Inhalation
Populations
Workers
Exposure forms
Vapour, dust

Status

Legal status
Accepted Tier 1 tool under REACH (ECHA Guidance R.14 v2.1)
Current version
Method as described in ECHA Guidance R.14 version 2.1
Version date
1 November 2012
Licence type
Free to use
Licence terms
Method published in ECHA guidance; reproduction authorised provided the source is acknowledged

Source

Official name
EMKG-Expo-Tool (exposure tool of the Einfaches Maßnahmenkonzept Gefahrstoffe)
Owner
Bundesanstalt für Arbeitsschutz und Arbeitsmedizin (BAuA), Germany
Official site
baua.de

Try it

Calculate EMKG-Expo-Tool with your own inputs

Loading the calculation...

NextSDS

2,437 SDSs. None left to chase.

NextSDS collects the safety data sheets you receive and keeps them current, so the inputs for EMKG-Expo-Tool and every other framework on this site are at hand.

Try NextSDS How it works