Quick answer
EMKG helps a competent person in Germany decide which protective measures a task with a hazardous substance needs, from minimum standards to a closed system or expert advice. It works from the safety data sheet and a walk through the workplace, separately for breathing in and for skin contact. It gives no exposure value; for that, BAuA has the separate EMKG-Expo-Tool.
What it is
EMKG stands for Einfaches Maßnahmenkonzept Gefahrstoffe, an easy to use control scheme for hazardous substances from the German Federal Institute for Occupational Safety and Health (BAuA). It is an action guide for the risk assessment of tasks with hazardous substances under the German Hazardous Substances Ordinance (GefStoffV), written for safety specialists and other competent persons. The current booklet is version 2.2 from May 2012. The inhalation part follows the approach of the British COSHH Essentials. Each result links to BAuA protection guides (Schutzleitfäden) for common tasks.
Does it apply to you?
It fits employers in Germany, and their safety specialists, who need a structured way to choose measures for supplied products.
| Use it for | Do not use it for |
|---|---|
| Tasks with supplied hazardous substances and mixtures (solids and liquids) | Fire and explosion hazards: these need a separate assessment |
| Substances with or without a German exposure limit (AGW, TRGS 900) | Substances formed in the task, such as welding fume, exhaust or decomposition products |
| Skin contact, including wet work | Demolition, remediation, cleaning and recycling where unknown substances are released |
| Industrial handling of gases | |
| Environmental hazards |
EMKG is not mandatory. TRGS 400 names it as an information source for hazards and protective measures.
How it works
Before the eight steps, a step 0 checks that the SDS is plausible, whether a safer substitute exists and whether the hazard is low.
- Hazard group for inhalation A to E. From the classification of the product. If the substance has a German exposure limit (AGW), the limit value sets the group instead: the lower the limit, the higher the group.
- Amount. Small (grams or millilitres), medium (kilograms or litres) or large (tonnes or cubic metres). In doubt, take the higher group.
- Release group. Liquids: low, medium or high from the boiling point (above 150 °C, 50 to 150 °C, below 50 °C at room temperature) or the vapour pressure, and the working temperature. Water based solutions of low volatile substances that are not sprayed count as low; aerosols count as high. Solids: low (pellets, wax, granules), medium (coarse powder) or high (fine powder).
- Measures for inhalation. A table gives measure level 1 (minimum standards), 2 (technical measures such as local exhaust ventilation), 3 (closed system) or expert advice. Group E always needs expert advice. For 15 minutes a day or less, the level can drop by one, except for irritants to the airways, corrosives, respiratory sensitisers and strongly smelling substances.
- Hazard group for skin HA to HE. From the classification, with extra weight for substances that pass through the skin. Wet work always needs basic skin measures.
- Skin contact. Small area (splashes) or large area (whole hand), short (under 15 minutes a day) or long.
- Skin measures. Low, extended or high need for measures; high means substitution or a closed system.
- Effectiveness check. Check that the measures work, including compliance with the exposure limit.
| Result | Meaning |
|---|---|
| Measure level 1 | Minimum standards and general protective measures |
| Measure level 2 | Technical measures to reduce emissions, for example local exhaust ventilation |
| Measure level 3 | Closed system |
| Expert advice | Get specialist help |
| Skin: low, extended, high | Basic skin protection, extended skin protection, or substitution or a closed system |
What you need from your safety data sheets
| Input | Where on the SDS |
|---|---|
| Classification of the product (not of the components) | Section 2 |
| German exposure limit (AGW), if any | Section 8 |
| Skin absorption | Sections 8 and 11 |
| Boiling point or vapour pressure (lowest value of a range) | Section 9 |
| Physical form | Section 9 |
| Amount, duration, skin contact area, working temperature | Not on the SDS: from your workplace |
What NextSDS does with it
NextSDS runs the EMKG measures scheme per product and workplace. It reads the hazard groups for inhalation, skin, eyes, fire and storage from the H-statements on the SDS, asks for the quantity, release and skin contact, and gives the control level per route with the matching control guidance sheets.
| Check | SDS data used | What it tells you |
|---|---|---|
| Risk assessment | Sections 2, 3 and 9, quantities per workplace | EMKG control level per route and workplace, with the control guidance sheets |
| Exposure limits | Section 3 against the German limit list | Which products contain a substance with an exposure limit |
| Exposure and PPE | Section 8 | Exposure routes, EMKG exposure class and PPE per body part |
Countries
| Country | Role | Basis |
|---|---|---|
| Owner | BAuA publication EMKG Version 2.2 (Stand Mai 2012), action guide for the risk assessment under GefStoffV | |
| Recommended | TRGS 400 (Ausgabe Juli 2017, GMBl 2017 Nr. 36 S. 638) Nummer 5.1 (7) Nr. 6 lists EMKG as an information source for hazards and protective measures |
Limitations
- The version 2.2 booklet is based on the old R phrases. For current SDSs with H statements you need the BAuA CLP module.
- Qualitative: no exposure value.
- No published validation of the full scheme was found; the exposure part was evaluated separately.
- Fire and explosion hazards, process fumes and gases are outside the scheme.
Key dates
| Date | Event |
|---|---|
| July 2017 | TRGS 400 names EMKG as an information source |
| May 2012 | EMKG version 2.2, adapted to the GefStoffV 2010 |
Frequently asked questions
Is EMKG mandatory in Germany?
No. TRGS 400 lists it among the information sources for the risk assessment. BAuA presents it as one way to work in a standardised way that meets the TRGS 400 criteria.
What is the difference between EMKG and the EMKG-Expo-Tool?
EMKG gives measures, such as local exhaust ventilation or a closed system. The EMKG-Expo-Tool gives an exposure range in mg/m3 or ppm to compare with an exposure limit.
Which data from the safety data sheet does EMKG use?
The classification in section 2, the German exposure limit in section 8 if there is one, and the boiling point or vapour pressure and physical form in section 9.
Does EMKG cover fire and explosion risks?
No. Physical and chemical hazards such as fire and explosion need a separate assessment.
Related frameworks
- EMKG-Expo-Tool: BAuA’s exposure tool, the quantitative part of EMKG.
- COSHH Essentials: the British scheme the approach is based on.
- ILO International Chemical Control Toolkit: international version of the same approach.
- Stoffenmanager: named next to EMKG as an information source in TRGS 400.
Official sources
- EMKG, BAuA
- TRGS 400 Gefährdungsbeurteilung für Tätigkeiten mit Gefahrstoffen, Nummer 5, AGS and BAuA, July 2017 (GMBl 2017 Nr. 36 S. 638), text published by the BGN
Based on research of 28 November 2026. This page is not legal advice; always check the official text.