Quick answer
COSHH Essentials tells you what kind of control a task with a solid or liquid chemical needs: general ventilation, engineering control, containment or expert advice. It works from the H statements, the amount and the dustiness or volatility, which you take from the safety data sheet. It does not give an exposure value, so do not use it to show compliance with an exposure limit.
What it is
COSHH Essentials is a control banding scheme from the Health and Safety Executive (HSE) in Great Britain. It was first published in 1999 as HSG193 and was developed for small and medium sized employers. The current technical basis is the CLP edition from January 2017, which uses H statements instead of the old R phrases. Each result links to HSE control guidance sheets that describe good practice for common tasks. HSE states that the scheme is not intended to be used as an exposure model.
Does it apply to you?
It fits employers who need a first, simple check of the controls for supplied chemicals.
| Use it for | Do not use it for |
|---|---|
| Liquids and solids handled at work | Gases, and liquids used above their boiling point |
| Supplied products with a CLP classification | Dusts and fumes made by the process, such as welding fume or wood dust |
| Mixtures you make yourself, such as dilutions | Showing compliance with an exposure limit (OEL or DNEL) |
| Spraying and other tasks that form aerosols, with extra care | Fire, explosion and environmental risks |
Following the guidance is not compulsory, but HSE says you will normally be doing enough to comply with the COSHH Regulations 2002.
How it works
- Hazard group. The H statements place the product in hazard group A (lowest) to E (highest). For example H315 and H319 give A, H302 gives B, H314 and H317 give C, H351 and H360 give D, and H334, H340 and H350 give E. The highest group counts. Products that can harm the skin or eyes also get the flag S.
- Your own mixtures. For mixtures you make, the group follows set percentage rules for the components. Water counts as group A.
- Volatility or dustiness. Liquids are low, medium or high volatility from the boiling point (above 150 °C, 50 to 150 °C, below 50 °C at room temperature) and the process temperature. Solids are low, medium or high dustiness from their form: pellets, granules or fine powder.
- Amount. Small (grams or millilitres), medium (kilograms or litres) or large (tonnes or cubic metres) per task.
- Control approach. A published table combines these into control approach 1 to 4. Group E always gives 4.
- Adjustments. A task of less than 15 minutes a day lowers approach 3 to 2 and 2 to 1. For spraying and other aerosol tasks HSE advises a stricter approach than the table gives.
- Respiratory protection. A separate table gives the protection factor needed if respiratory protective equipment is used, as the last line of defence.
| Result | Meaning |
|---|---|
| Control approach 1 | General ventilation and good practice |
| Control approach 2 | Engineering control, typically local exhaust ventilation |
| Control approach 3 | Containment |
| Control approach 4 | Special case: get expert advice |
| S | Controls for skin and eye contact needed |
What you need from your safety data sheets
| Input | Where on the SDS |
|---|---|
| H statements of the product | Section 2.1 |
| H statements and concentrations of the components (for your own mixtures) | Section 3 |
| Physical form (solid or liquid) | Section 9 |
| Boiling point or vapour pressure | Section 9 |
| Particle form or dustiness, if given | Section 9 |
| Amount, duration and task | Not on the SDS: from your workplace |
What NextSDS does with it
| Check | SDS data used | What it tells you |
|---|---|---|
| Classification and hazard levels | H statements, section 2 and 3 | The COSHH hazard group A to E and the S flag per product |
| Physical hazards | Boiling point and form, section 9 | The volatility or dustiness band |
| Risk assessment | Hazard group, band, amount per workplace | Control approach 1 to 4 per task, with the shorter duration and aerosol rules |
| Exposure and PPE | Section 8 | The respiratory protection factor next to the PPE on the SDS |
NextSDS applies the official HSE tables without its own changes. Like the scheme itself, the result is a control approach, not an exposure value.
Countries
| Country | Role | Basis |
|---|---|---|
| Owner | HSE technical basis (CLP edition, 01/17): issued by HSE; following it 'is not compulsory' but 'you will normally be doing enough to comply with the law' (COSHH Regulations 2002) |
The German EMKG and the ILO International Chemical Control Toolkit are adaptations of the same approach.
Limitations
- Qualitative: no exposure value, so no comparison with an exposure limit.
- The hazard group comes from the classification only. A substance with a very low exposure limit can still land in a middle group.
- Products with carcinogens, mutagens or respiratory sensitisers always end in approach 4, whatever the task.
- The S flag is set by any skin hazard component, whatever its concentration.
- Reaction hazards (for example EUH031) and wet work are outside the scheme.
- HSE reports validation for some general ventilation and engineering control scenarios; validation of containment scenarios was still ongoing.
Key dates
| Date | Event |
|---|---|
| 16 March 2023 | Last update of the HSE COSHH essentials page |
| January 2017 | Technical basis, CLP edition: H statements replace R phrases |
| 1999 | First publication as HSG193 (now withdrawn) |
Frequently asked questions
Does COSHH Essentials give an exposure in mg/m3?
No. HSE says it is not an exposure model. For an exposure range from the same matrix, see the EMKG-Expo-Tool.
Is COSHH Essentials mandatory in Great Britain?
No. It is HSE guidance. Following it normally means you do enough to comply with the COSHH Regulations 2002.
Which parts of the safety data sheet do I need?
The H statements in section 2, the components in section 3 when you dilute or mix the product yourself, and the physical form and boiling point in section 9.
What does control approach 4 mean?
It is a special case where you need expert advice. It applies for example to every product with H334, H340, H341 or H350.
Can I use it for gases or welding fume?
No. Gases, liquids above their boiling point and dusts or fumes formed in the process are outside the scheme.
Related frameworks
- ILO International Chemical Control Toolkit: international version with the same control approach table.
- EMKG: German control banding scheme based on the same approach.
- EMKG-Expo-Tool: gives an exposure range from the same exposure matrix.
- Stoffenmanager: banding and exposure tool with more task detail.
- Seirich: French INRS tool that ranks chemical risks and builds an action plan.
Official sources
- COSHH essentials, HSE, page last updated 16 March 2023
- COSHH essentials: Controlling exposure to chemicals, a simple control banding approach, HSE, CLP edition, January 2017
Based on research of 28 November 2026. This page is not legal advice; always check the official text.