European Union

22 frameworks for chemical exposure and risk assessment with a role in the European Union: owner 3, official 2, recommended 4, accepted 10, used 3.

Owner · 3

Publishes or maintains the method.

FrameworkTypeBasis
ChesarIn progress Exposure model, Tier 1 (screening) Developed and published by ECHA to support REACH chemical safety assessments and reports (REACH Art. 14 and Annex I); Chesar Platform released 2 June 2026 on ECHA Cloud Services
EN 689Light mapping Guidance, Tier 3 (measurement based) European standard by CEN/TC 137, approved 2 March 2018, supersedes EN 689:1995; CEN members in 34 countries must implement it (EN 689:2018 European foreword)
EUSESLight mapping Exposure model, Tier 1 (screening) Commissioned by the European Commission, developed by RIVM for the European Chemicals Bureau, supervised by an EU working group (RIVM 601900005, Preface p. ii); distributed by ECHA; ECHA news 2 June 2026: the Chesar Platform will gradually replace Chesar, EUSES 2.2.0 and the biocides Excel tools To be verified

Official · 2

Named in law or by the competent authority.

FrameworkTypeBasis
Biocides human exposure guidance (HEEG/HEAdhoc)Light mapping Guidance, Tier 1 (screening) Guidance on Regulation (EU) No 528/2012 (BPR), applies to active substance approval and product authorisation (Biocides Human Health Exposure Methodology v1, Foreword; Vol. III Part B v1.0 preface)
EFSA OPEX (AOEM)Light mapping Exposure model, Tier 1 (screening) Regulation (EC) No 1107/2009 requires exposure risk assessment for operators, workers, residents and bystanders (EFSA 2022 section 1); the 2014 guidance was taken note of by the Standing Committee with implementing provisions, last modified 24 January 2017 (EFSA 2022 section 1.1)

Recommended in official guidance of an authority.

FrameworkTypeBasis
BEATIn progress Exposure model, Tier 2 (refined) ECHA Biocides Human Health Exposure Methodology v1 (Oct 2015) section 3.2.3 p. 145 and section 6.3.1 pp. 223 to 224, under the Biocidal Products Regulation (EU) 528/2012
ConsExpoIn progress Exposure model, Tier 2 (refined) RIVM: 'a recommended tool for higher tier assessments for consumer exposure under REACH'; ECHA commissioned the ConsExpo Web export to Chesar manual; ECHA BPC Recommendation no. 6 (2016) recommends ConsExpo for consumer biocidal products [secondary: Danish EPA 2018]; R.14 v2.1 refers to ConsExpo for ingestion
EASE 2.0In progress Exposure model, Tier 1 (screening) Historical, pre-REACH: named in the EU Technical Guidance Document 1996 and revised TGD 2003 for new and existing substances (Northage 2005; HERAG FS 01 p. 5). Under REACH only the basis of ECETOC TRA (ECHA R.14 v2.1 p. 20); not listed as a REACH tool
ECELIn progress Guidance, Tier 2 (refined) ECHA Biocides Human Health Exposure Methodology v1 (Oct 2015) section 3.3.1 pp. 150 to 151 reproduces the Fransman et al. 2008 efficacy table as consultable default reduction factors; ART multipliers (an R.14 Tier 2 tool) are based on ECEL

Accepted · 10

Accepted by regulators, for example in REACH guidance.

FrameworkTypeBasis
ARTComplete Exposure model, Tier 2 (refined) ECHA Guidance R.14 v2.1 (2012) section R.14.5.3: named Tier 2 tool for occupational exposure in REACH chemical safety reports
ECETOC TRA consumerComplete Exposure model, Tier 1 (screening) ECETOC TR 114 section 1.2 reports that ECHA Guidance R.15 recognises the TRA as a preferred Tier 1 consumer tool; consumer TRA embedded in ECHA Chesar (TR 131)
ECETOC TRA environmentIn progress Release model, Tier 1 (screening) TR 114 section 1.2: ECHA R.16 names EUSES as preferred tool, but ECHA incorporated the TRA release module into Chesar; TRA ENV implements the R.16 / EU TGD algorithms (TR 107 section 4.3.1)
ECETOC TRA workerComplete Exposure model, Tier 1 (screening) ECHA Guidance R.14 v2.1 (2012) section R.14.4.8: the preferred Tier 1 tool; worker TRA embedded in ECHA Chesar (TR 114 section 1.2; TR 131); REACH Annex I 5.2.5 allows models; also applies in the EEA
EMKG-Expo-ToolComplete Exposure model, Tier 1 (screening) ECHA Guidance R.14 v2.1 (Nov 2012) §R.14.4.9: Tier 1 tool for REACH chemical safety assessment, 'sufficiently conservative for a Tier 1 tool and can thus be used as such'
IH MOD / NF-FFIn progress Exposure model, Tier 2 (refined) ECHA Guidance R.14 v2.1 (2012) section R.14.5: Tier 2 by any suitable method that is valid and sufficiently accurate; IH MOD is not named
MEASE 2In progress Exposure model, Tier 1 (screening) ECHA Guidance R.14 v2.1 (Nov 2012) section R.14.4.8.3 p. 25 describes MEASE as a first Tier tool for metals and inorganic substances
RISKOFDERMIn progress Exposure model, Tier 2 (refined) ECHA Guidance R.14 v2.1 (Nov 2012) section R.14.5.2 pp. 36 to 39 describes RISKOFDERM as a Tier 2 dermal model for REACH; section R.14.5 allows any suitable valid Tier 2 method
StoffenmanagerComplete Exposure model, Tier 1 (screening) ECHA Guidance R.14 v2.1 §R.14.5.1 (higher Tier tool for REACH chemical safety reports)
Welding fume NF/FFComplete Exposure model, Tier 2 (refined) ECHA Guidance R.14 section R.14.5: Tier 2 assessment with any suitable, valid method

Used · 3

Common practice, without a formal status.

FrameworkTypeBasis
NanoSaferIn progress Control banding, Tier 1 (screening) Listed in the NanoReg2 Safe Innovation Approach toolbox hosted by RIVM (page of 8 Sep 2017, modified 2 Nov 2018); evaluated in EU FP7 NANoREG D3.08 and developed in H2020 caLIBRAte
SprayExpoIn progress Exposure model, Tier 2 (refined) Listed as a higher tier mechanistic spray model in EU exposure model reviews for biocide and occupational spraying (Hahn et al. 2021, CC BY; Danish EPA 2018)
TNO NEQLight mapping Exposure model, Tier 1 (screening) Developed in EU H2020 SbD4Nano for safe by design decisions (Vermoolen et al. 2025, acknowledgements) To be verified

The basis is the law, authority page or official guidance that gives the framework its role. Not legal advice; always check the official text.