Quick answer
ECETOC TRA consumer is a free screening tool that estimates how much of a substance a consumer breathes in, gets on the skin or swallows when using a product or article. It uses three simple equations with fixed, deliberately cautious defaults per product or article category. Use it to screen consumer uses in a REACH exposure scenario; when the risk ratio is above 1, refine with better data or a higher tier model such as ConsExpo.
What it is
The consumer part of the Targeted Risk Assessment (TRA) is published by ECETOC, a scientific association funded by the chemical industry in Brussels. Version 2 (2009) was developed with an expert group of ECHA, ECETOC, RIVM, BfR, INERIS and the Danish EPA to match the REACH product categories (PC), article categories (AC) and the ECHA Tier 1 equations (ECETOC TR 107). Version 3 (2012) added user defined subcategories, a cap at the saturated vapour concentration, room ventilation and transfer factors. Version 3.1 (2014) added frequency bands for products used less than daily and an indoor or outdoor choice. It exists as a standalone workbook and as a module of the Integrated TRA, and ECHA’s Chesar uses it for consumer estimates.
Does it apply to you?
TRA consumer is mainly a tool for REACH registrants and downstream users who must show safe use of a substance in consumer products. It fits when:
- the substance is in a consumer product or article covered by the REACH categories with defaults, such as adhesives, air care, paints, fillers, fuels, lubricants, polishes, cleaning products, textiles, leather, paper, rubber, wood and plastic articles;
- you need a quick, conservative screen of skin, inhalation and (for children) oral exposure.
It does not cover food, food contact materials, medicines, accidents, or the sum of exposures from several products (TR 107 section 3.1). If you assess your own workers, use ECETOC TRA worker instead.
How it works
- Choose the subcategory. For example “liquid cleaners” or “aerosol spray can”. Each has default routes, amounts, contact areas, durations and frequencies.
- Skin. Exposure depends on the fraction of the substance in the product, the skin area in contact, the product layer on the skin (0.01 cm default for liquids), the number of uses per day and body weight (60 kg adult, 10 kg child) (TR 107 section 3.1.2).
- Inhalation. Exposure depends on the amount used per event, the fraction released to air, the exposure time, the inhalation rate and the room volume. For non-sprays the fraction released depends on vapour pressure: 1 at 10 Pa or more, then 0.1, 0.01 and 0.001 for lower bands; for sprays it is 1 (TR 107 Table 4). Ventilation lowers the result and the air concentration cannot exceed the saturated vapour concentration (TR 114 section 3).
- Oral. Used for child mouthing of articles and a few products such as finger paints.
- Less frequent use (optional). With supporting data, the estimate can be multiplied by 0.2 (weekly to monthly), 0.04 (monthly to every six months) or 0.01 (less often) (TR 124).
- Risk. Each route is divided by its DNEL for the general population, and the route ratios are added up per subcategory (TR 114 section 3.5).
What you need from your safety data sheets
| Input | Where on the SDS |
|---|---|
| Fraction of the substance in the product | Section 3 |
| Vapour pressure | Section 9 |
| Molecular weight | Section 9 |
| Spray or not | Product type, section 1 and section 9 |
| Identified consumer uses (product category) | Section 1.2 and the exposure scenario |
| DNELs for the general population | Exposure scenario or REACH registration, sometimes section 8.1 |
Amounts, contact areas and use frequencies come from the tool’s defaults, not from the SDS.
What NextSDS does with it
NextSDS has implemented TRA consumer version 3.1, as shipped in the ECETOC Integrated TRA 3.2. For each of the 46 product and article subcategories with defaults it calculates skin, oral and inhalation exposure and the risk ratios against the DNELs for the general population, using the fraction of the substance, the vapour pressure and the molecular weight from the SDS. The changes the tool allows, such as a different fraction, contact area or amount, and own subcategories with a use frequency band or outdoor use, are supported. On 840 test cases the results and the tool’s messages equal the original ECETOC workbook. The worst case summary per product category (the sentinel product view) is not offered yet; the results per subcategory are complete. Which subcategory fits a product is a choice made per product and recorded with the assessment.
Countries
| Country | Role | Basis |
|---|---|---|
| Owner | ECETOC AISBL, Brussels, publishes the tool and Technical Reports TR 107, 114, 124, 131 | |
| Accepted | ECETOC TR 114 section 1.2 reports that ECHA Guidance R.15 recognises the TRA as a preferred Tier 1 consumer tool; consumer TRA embedded in ECHA Chesar (TR 131) |
Limitations
- It assumes daily use and full, instant release for volatile substances and sprays, so results are very conservative (TR 107; TR 124).
- It assumes 100% absorption through skin, lungs and gut (TR 107; TR 124).
- Skin and oral estimates have no event duration and are compared with long term DNELs (TR 131 section 3.1).
- Its predictions remain much higher than those of Tier 2 models such as ConsExpo (TR 124).
- Exposures from different products are not added up (TR 107 section 3.1).
Key dates
- Integrated TRA 3.2 released; the consumer module is still version 3.1.
- Technical Report 131 explains frequency bands versus the ECHA R.15 duration approach.
- Consumer version 3.1 (Technical Report 124).
- Version 3 (Technical Report 114).
- Version 2 aligned with REACH product and article categories (Technical Report 107).
Frequently asked questions
Why does TRA consumer overestimate so much?
Daily use, full release to air, full absorption and no event duration are built into the defaults. That keeps it safe as a first screen, but far from typical real use.
Can I lower the estimate for a product used once a month?
Yes, with the version 3.1 frequency band (factor 0.04 for monthly to six monthly use), when you have data that support the lower frequency (TR 124).
Is the result the same as in Chesar?
Chesar uses the TRA consumer equations, but it also offers the ECHA R.15 (2016) approach that adjusts the DNEL for duration and frequency. The standalone tool does not (TR 131 section 3.1).
Do I need this tool as an employer?
Usually not. It assesses consumers using products, not workers. For workplace tasks, ECETOC TRA worker or another worker model fits.
Related frameworks
- ECETOC TRA worker: the worker module of the same tool.
- ECETOC TRA environment: releases to the environment for the same exposure scenario.
- ConsExpo: the RIVM Tier 2 consumer model used to refine a TRA screen.
- Chesar: ECHA’s chemical safety report tool, which uses the TRA consumer equations.
Official sources
- ECETOC Targeted Risk Assessment (TRA), ECETOC, official tool page, consumer version 3.1, June 2014
- ECETOC Technical Report No. 107, Addendum to ECETOC Targeted Risk Assessment Report No. 93, December 2009
- ECETOC Technical Report No. 114, ECETOC TRA version 3: Background and Rationale for the Improvements, July 2012
- ECETOC Technical Report No. 124, Addendum to TR114: Technical Basis for the TRA v3.1, June 2014
- ECETOC Technical Report No. 131, Targeted Risk Assessment: Further Explanation of the Technical Basis of the TRA v3.1, February 2018
- Guidance on information requirements and chemical safety assessment, Chapter R.15: Consumer exposure assessment, ECHA
- Regulation (EC) No 1907/2006 (REACH), Annex I, European Union
This page is not legal advice; always check the official text.