Quick answer
Chesar is the free ECHA software that many REACH registrants use to write their chemical safety report and the exposure scenarios that come attached to an extended safety data sheet. As a company that receives safety data sheets, you do not need Chesar yourself. Knowing how it works helps you read the exposure scenario annex and check whether your use and your conditions are covered.
What it is
Chesar stands for Chemical Safety Assessment and Reporting tool. ECHA, the European Chemicals Agency, built it to support the chemical safety assessment that REACH requires. Chesar has no exposure model of its own: it runs the ECETOC TRA worker and consumer modules and the EUSES and TRA release logic for the environment, and it can take in results from other tools. From the assessment it produces the chemical safety report and the exposure scenarios for communication, which suppliers annex to the safety data sheet. On 2 June 2026 ECHA released the new Chesar Platform on ECHA Cloud Services, which brings Chesar and EUSES together.
Does it apply to you?
Chesar is for:
- REACH registrants (manufacturers and importers) that must prepare a chemical safety report, which REACH Article 14 requires for substances at 10 tonnes or more per year;
- downstream users that write their own chemical safety report because their use is not covered by the supplier.
It is not designed for a workplace risk assessment under national occupational safety and health law. If you only receive safety data sheets, you meet Chesar through the exposure scenarios annexed to them. For your own assessment, a control banding or screening tool fits better.
How it works
- Load the substance: identity, properties and the derived no effect levels (DNELs and PNECs) from the IUCLID dossier.
- Map the uses: life cycle stages and contributing activities, described with the REACH use descriptors (PROC, PC, ERC, SU).
- Estimate exposure for each contributing activity: with the embedded ECETOC TRA worker or consumer module, with the EUSES or TRA release logic for the environment, or by importing a result from another tool, such as ConsExpo, ART or measurements (Chesar 3).
- Compare with the limits: the risk characterisation ratio is the exposure divided by the DNEL (or PEC divided by PNEC), for each activity and combined.
- Report: Chesar generates the chemical safety report sections and the exposure scenario for communication that goes with the safety data sheet.
The embedded TRA follows the ECETOC TRA rules with a few Chesar settings, such as a default operating temperature of 40 C (ECETOC TR 131).
What you need from your safety data sheets
Chesar itself is used by the supplier. These are the places on the SDS where its results show up and where its inputs come from:
| Input or output | Where on the SDS |
|---|---|
| Substance identity and composition | Sections 1 and 3 |
| Identified uses and use descriptors | Section 1.2 and the exposure scenario annex |
| DNELs and PNECs | Section 8.1 |
| Conditions of use (duration, concentration, ventilation, LEV) | Section 8.2 and the exposure scenario annex |
| Protective equipment (gloves, respiratory protection) | Section 8.2 and the exposure scenario annex |
| Physical properties (vapour pressure, physical state, dustiness) | Section 9 |
What NextSDS does with it
NextSDS does not rebuild Chesar. It runs its own ECETOC TRA worker engine, which covers the worker module embedded in Chesar, so you can recalculate a worker estimate for your own conditions. NextSDS reads the uses, DNELs and conditions of use from the safety data sheets you receive. An export of NextSDS estimates in a form that can be entered in Chesar is planned.
Countries
| Country | Role | Basis |
|---|---|---|
| Owner | Developed and published by ECHA to support REACH chemical safety assessments and reports (REACH Art. 14 and Annex I); Chesar Platform released 2 June 2026 on ECHA Cloud Services |
Limitations
- The embedded estimates cover what ECETOC TRA and EUSES cover: vapours and dusts, partly fumes and gases; mists, fibres and nanomaterials are outside.
- Higher tier models such as ART or Stoffenmanager are not computed inside Chesar; their results are entered as external estimates.
- Chesar is a REACH tool: an exposure scenario shows the conditions the supplier assessed, not the conditions at your site.
Key dates
- ECHA releases the Chesar Platform on ECHA Cloud Services.
- RIVM publishes the manual for importing ConsExpo Web results into Chesar 3.
- ECETOC TRA worker and consumer modules are used in Chesar.
Frequently asked questions
Do I need Chesar to manage the safety data sheets I receive?
No. Chesar is used by registrants to write the chemical safety report. You use its output: the exposure scenarios annexed to an extended safety data sheet.
Is Chesar mandatory under REACH?
No tool is prescribed. REACH Article 14 requires a chemical safety report for substances at 10 tonnes or more per year; Chesar is ECHA’s free tool to prepare it.
Why do exposure scenarios list PROC codes and conditions of use?
Chesar maps each use with REACH use descriptors such as PROC codes, and calculates exposure for set conditions of use. The scenario shows those conditions, so you can check that your task and your controls match.
Is the exposure estimate in Chesar the same as in ECETOC TRA?
Nearly. Chesar embeds the ECETOC TRA modules, with a few different settings such as a default operating temperature of 40 C (ECETOC TR 131).
Related frameworks
- ECETOC TRA worker: the worker module embedded in Chesar.
- ECETOC TRA consumer: the consumer module embedded in Chesar.
- ECETOC TRA environment: release estimates used for the environment.
- ConsExpo: consumer tool whose results can be imported into Chesar 3.
- ART and Stoffenmanager: higher tier worker models whose results enter as external estimates.
- IH MOD and near field / far field models: physical models for higher tier estimates.
- BEAT: biocides exposure tool in the ECHA biocides methodology.
Official sources
- Chesar Platform, ECHA
- ECHA launches new Chesar Platform for chemical risk assessment, ECHA, 2 June 2026
- ConsExpo Web export to Chesar, Manual, RIVM for ECHA, version 1, 2017
- ECETOC TR 131, Further Explanation of the Technical Basis of the TRA v3.1, ECETOC, February 2018
- Regulation (EC) No 1907/2006 (REACH), Article 14 and Annex I
This page is not legal advice; always check the official text.