Quick answer
ECEL tells you how much a control measure, such as local exhaust ventilation (LEV), enclosure or wet suppression, typically reduces exposure, based on published measurements. It does not estimate exposure itself. Use it to back up the reduction you assume for a control in your risk assessment, or to compare control options.
What it is
ECEL is a library of measured efficacies of risk management measures, built by TNO in the Netherlands. The first version (2008) collected 433 efficacy values from 90 peer reviewed papers, grouped into six types of control. Version 3.0 (2020), funded by the chemical industry research programme Cefic LRI, holds more than 3300 occupational records and more than 1100 environmental records. It runs as a free web tool on the TNO DIAMONDS platform. Exposure models such as ART use ECEL to set their control factors.
Does it apply to you?
ECEL is useful when:
- you assume that a control measure lowers exposure and need to justify by how much;
- you compare options, for example LEV against general ventilation, for a task;
- you prepare a REACH or biocides exposure assessment with control factors;
- you look at emission controls in the environmental module.
It does not apply when you need an exposure level: ECEL gives ratios only, so combine it with a model or measurements. Also check that the control is not already counted in the model or study you use, so you do not count it twice.
How it works
- Choose the control: for example enclosure, LEV, specialised ventilation, general ventilation, suppression or separation of workers.
- Filter the records (version 3.0): by substance, activity, process and study quality (strong, moderate, limited).
- Read the efficacy: version 3.0 gives the median reduction of the selected records with a 95% credible interval from a Bayesian bootstrap, and a summary PDF with references.
- Use it in a model: an efficacy of e% becomes a factor of (1 minus e/100) on the exposure.
Average efficacies from ECEL version 1, as reproduced by ECHA (2015, p. 151):
| Control | Records | Average efficacy | 95% confidence interval |
|---|---|---|---|
| Enclosure | 14 | 50% | 4 to 74% |
| Local exhaust ventilation | 280 | 82% | 78 to 84% |
| Specialised ventilation | 14 | 87% | 73 to 94% |
| General ventilation | 42 | 43% | 17 to 61% |
| Suppression techniques | 69 | 83% | 77 to 88% |
| Separation of workers | 14 | 87% | 71 to 94% |
What you need from your safety data sheets
| Input | Where on the SDS |
|---|---|
| Recommended engineering controls (LEV, enclosure, ventilation) | Section 8.2 |
| Identified uses and the activity | Section 1.2, and the exposure scenario annex if attached |
| Physical state and properties (to filter similar records) | Section 9 |
| Controls actually in place | Not on the SDS: workplace data |
Section 8.2 gives the supplier’s recommendations, not the controls at your site, so check what is really installed.
What NextSDS does with it
NextSDS has researched ECEL but does not use it directly. ECEL values reach NextSDS indirectly through the control factors of the ART model. NextSDS reads the recommended controls from section 8.2 of your safety data sheets so you can compare them with the controls in place.
Countries
| Country | Role | Basis |
|---|---|---|
| Owner | Developed and hosted by TNO (Fransman et al. 2008; Cefic LRI B15 executive summary) | |
| Recommended | ECHA Biocides Human Health Exposure Methodology v1 (Oct 2015) section 3.3.1 pp. 150 to 151 reproduces the Fransman et al. 2008 efficacy table as consultable default reduction factors; ART multipliers (an R.14 Tier 2 tool) are based on ECEL | |
| International | Used | Used for control factors in ART (localized controls), MEASE (RMM efficiencies) and NanoSafer (control recommendations) |
Limitations
- Small groups have wide uncertainty; partial enclosure, for example, averages 23% with an interval from minus 103% to 70% (ECHA 2015, p. 151).
- Efficacy varies a lot within a group, depending on study design, sampling strategy and measurement type; the authors advise adding expert opinion (Fransman et al. 2008).
- Data are uneven in version 3.0: 1246 LEV records from 360 studies, but only 52 records from 8 studies for product or substance control.
- ECEL gives reductions, not exposure levels.
- Version 3.0 needs a free registration on TNO DIAMONDS.
Key dates
- ECEL version 3.0 released on TNO DIAMONDS.
- ECEL version 2.0 web library completed.
- ECHA biocides methodology reproduces the ECEL version 1 table.
- ECEL version 1 published by Fransman et al.
Frequently asked questions
Is ECEL an exposure model?
No. It gives the reduction a control achieves. You still need a model or measurements for the exposure level.
Can I assume 82% for any local exhaust ventilation?
Not automatically. ECHA’s biocides methodology allows the table as a default with expert judgement, and warns not to count LEV twice if the model or study already includes it. REACH tools such as ART and ECETOC TRA have their own LEV factors.
Does my safety data sheet tell me which controls to use?
Section 8.2 lists the supplier’s recommended controls. ECEL helps you judge how much those controls typically reduce exposure.
Is ECEL free?
Yes. Version 3.0 is a free web tool on TNO DIAMONDS after registration.
Related frameworks
- ART: its localized control factors are based on ECEL.
- ECETOC TRA worker: REACH screening tool with its own LEV efficiencies.
- BEAT: biocides tool in the same ECHA methodology.
- IH MOD and near field / far field models: physical models where a control efficacy can scale the release or the concentration.
Official sources
- ECEL on TNO DIAMONDS, TNO, version 3.0
- ECEL 3.0 Integrated Risk Management Measure library, Cefic LRI, released 20 October 2020
- ECEL 3.0 executive summary, Cefic LRI / TNO
- Fransman et al. 2008, Development and evaluation of an exposure control efficacy library (ECEL), Annals of Occupational Hygiene 52(7)
- Biocides Human Health Exposure Methodology, ECHA (copy hosted by HSE), version 1, October 2015
This page is not legal advice; always check the official text.