EASE 2.0

EASE was the UK HSE expert system for workplace exposure used in EU risk assessments before REACH. It is no longer distributed but lives on in ECETOC TRA and MEASE.

Exposure model Tier 1 (screening) In progress Last reviewed 28 November 2026

Quick answer

EASE was the standard EU model for workplace exposure in risk assessments of new and existing substances before REACH. It is no longer distributed and should not be used for new assessments: its inhalation logic was never published and its skin module overestimates strongly. It still matters because the ECETOC TRA worker tool, used for many REACH exposure scenarios, is built on modified EASE values.

What it is

EASE stands for Estimation and Assessment of Substance Exposure. The UK Health and Safety Executive (HSE) first developed it in the early 1990s, on behalf of the EU, as a screening tool for new chemicals without measurements. It predicts a range of exposure from three ideas: how easily the substance becomes airborne, how it is used and how it is controlled. HSE’s National Exposure Database was the main data source for its exposure ranges. The Windows version 2.0, made with AIAI Edinburgh, appeared in August 1997 and was distributed to over 200 users worldwide.

Does it apply to you?

Not for new work. EASE matters in two cases:

  • Reading older EU documents. Risk assessment reports of new and existing substances made under the Technical Guidance Document (1996, revised 2003) often use EASE estimates.
  • Understanding REACH exposure scenarios. ECHA Guidance R.14 describes the ECETOC TRA worker tool as a modified version of EASE 2.0. The exposure scenarios on many safety data sheets come from TRA.

For a current first tier estimate use ECETOC TRA, or MEASE for metals. For more detail use a higher tier model.

How it works

  1. Describe the substance and the task. Physical state, tendency to become airborne (vapour pressure for liquids, dust type for solids), pattern of use (closed system, inclusion into a matrix, non dispersive, wide dispersive) and pattern of control (full containment, local exhaust ventilation, segregation, direct handling).
  2. Follow the decision tree to an end point with an exposure range. Inhalation ranges run from 0.001 to 1,000 ppm for volatile materials and from 0.001 to 50 mg/m3 for solids (ECETOC TR 93, Appendix J). The tree itself was never published.
  3. Read the skin range in mg/cm2/day from pattern of use, pattern of control and contact level (none, incidental, intermittent, extensive). With direct handling and wide dispersive use the ranges go from 0.1 to 1 (incidental) up to 5 to 15 mg/cm2/day (extensive). Without direct handling the result is “very low”.
  4. Interpret. The developers saw the outputs as broad estimates, to be adapted by experienced occupational hygienists.

What you need from your safety data sheets

Input Where on the SDS
Physical state (solid, liquid, gas) Section 9
Vapour pressure Section 9
Dust or particle characteristics Section 9
Uses and how the product is applied Section 1.2 and the exposure scenario
Exposure controls (ventilation, containment) Section 8 and the exposure scenario
Skin contact level Not on the SDS: your own task description

What NextSDS does with it

NextSDS does not calculate EASE. The model is obsolete, no longer distributed and its inhalation tree cannot be rebuilt from public sources. NextSDS uses EASE only as background to explain where ECETOC TRA values come from. For screening, NextSDS works with current models that use the same SDS data.

Countries

CountryRoleBasis
United KingdomOwnerDeveloped by HSE in the early 1990s; Windows version 2.0 produced by HSE in 1997 (Northage 2005, Ann Occup Hyg 49:99); used by HSE in risk assessment of new and existing chemicals (Tickner et al. 2005 abstract)
European UnionRecommendedHistorical, pre-REACH: named in the EU Technical Guidance Document 1996 and revised TGD 2003 for new and existing substances (Northage 2005; HERAG FS 01 p. 5). Under REACH only the basis of ECETOC TRA (ECHA R.14 v2.1 p. 20); not listed as a REACH tool

Limitations

  • Not transparent. Neither the structure nor the principles of EASE were published in the open literature (Tickner et al. 2005).
  • Inhalation often too high. In 62% of 28 end points EASE was generally higher than about 4,000 measurements, and comparable in 30% (Cherrie and Hughson 2005).
  • Skin estimates far too high. Creely et al. (2005) found “considerable overestimates” of skin exposure. For metals HERAG Fact Sheet 01 found overestimates by a factor of 35 to 550 and called the skin module “not suitable for regulatory risk assessment”.
  • Built on problem areas. The data came from HSE enforcement visits in known problem areas, and EASE assumes tonne quantities are handled (ECETOC TR 93; ECHA R.14 v2.1).
  • Weak on controls. Insufficient account of how well local exhaust ventilation works (ECETOC TR 93).

Key dates

Date Event
March 2005 Annals of Occupational Hygiene publishes papers on the history and validation of EASE
2003 EU Technical Guidance Document revised; HSE evaluation report on EASE 2.0
August 1997 EASE for Windows 2.0 released by HSE with AIAI Edinburgh
1996 EASE included in the first EU Technical Guidance Document
Early 1990s First MS-DOS version developed by HSE

Frequently asked questions

Can I still use EASE?

No. It is no longer distributed and it is not a REACH tool. Use ECETOC TRA, its successor for REACH, or a higher tier model.

Why does EASE still matter?

ECETOC TRA worker estimates are modified EASE values (ECHA Guidance R.14 v2.1), and MEASE uses the EASE skin exposure classes. Older EU risk assessment reports also rely on EASE.

Which SDS data did EASE use?

The physical state and vapour pressure or dust characteristics (section 9), the way the product is used and the controls in place (sections 1.2 and 8 and the exposure scenario).

Is EASE conservative?

Mostly, but not always. Studies found it often higher than measurements, and its skin module much too high. ECETOC found some underestimates, mainly for dusty solids.

  • ECETOC TRA worker: described in ECHA Guidance R.14 as a modified version of EASE 2.0.
  • MEASE 2: uses the EASE skin classes with measured values for metals.
  • TREXMO: keeps EASE descriptors for translation between exposure models.
  • ART: a later, higher tier tool that combines a model with measured data.

Official sources

This page is not legal advice; always check the official text.

Key facts

EASE 2.0

Scope

Type
Exposure model
Tier
1 (screening, historical)
Routes
Inhalation, dermal
Populations
Workers
Exposure forms
Vapour, gas, dust, fibres, liquid aerosols, skin contact

Status

Legal status
Historical: EU Technical Guidance Document 1996 and 2003; not a REACH tool, but the basis of ECETOC TRA
Current version
2.0
Version date
1997-08
Licence type
Not stated
Licence terms
No longer distributed

Source

Official name
EASE, Estimation and Assessment of Substance Exposure (EASE for Windows 2.0)
Owner
UK Health and Safety Executive (HSE), with AIAI Edinburgh
Official site
doi.org

NextSDS

2,437 SDSs. None left to chase.

NextSDS collects the safety data sheets you receive and keeps them current, so the inputs for EASE 2.0 and every other framework on this site are at hand.

Try NextSDS How it works