Quick answer
EASE was the standard EU model for workplace exposure in risk assessments of new and existing substances before REACH. It is no longer distributed and should not be used for new assessments: its inhalation logic was never published and its skin module overestimates strongly. It still matters because the ECETOC TRA worker tool, used for many REACH exposure scenarios, is built on modified EASE values.
What it is
EASE stands for Estimation and Assessment of Substance Exposure. The UK Health and Safety Executive (HSE) first developed it in the early 1990s, on behalf of the EU, as a screening tool for new chemicals without measurements. It predicts a range of exposure from three ideas: how easily the substance becomes airborne, how it is used and how it is controlled. HSE’s National Exposure Database was the main data source for its exposure ranges. The Windows version 2.0, made with AIAI Edinburgh, appeared in August 1997 and was distributed to over 200 users worldwide.
Does it apply to you?
Not for new work. EASE matters in two cases:
- Reading older EU documents. Risk assessment reports of new and existing substances made under the Technical Guidance Document (1996, revised 2003) often use EASE estimates.
- Understanding REACH exposure scenarios. ECHA Guidance R.14 describes the ECETOC TRA worker tool as a modified version of EASE 2.0. The exposure scenarios on many safety data sheets come from TRA.
For a current first tier estimate use ECETOC TRA, or MEASE for metals. For more detail use a higher tier model.
How it works
- Describe the substance and the task. Physical state, tendency to become airborne (vapour pressure for liquids, dust type for solids), pattern of use (closed system, inclusion into a matrix, non dispersive, wide dispersive) and pattern of control (full containment, local exhaust ventilation, segregation, direct handling).
- Follow the decision tree to an end point with an exposure range. Inhalation ranges run from 0.001 to 1,000 ppm for volatile materials and from 0.001 to 50 mg/m3 for solids (ECETOC TR 93, Appendix J). The tree itself was never published.
- Read the skin range in mg/cm2/day from pattern of use, pattern of control and contact level (none, incidental, intermittent, extensive). With direct handling and wide dispersive use the ranges go from 0.1 to 1 (incidental) up to 5 to 15 mg/cm2/day (extensive). Without direct handling the result is “very low”.
- Interpret. The developers saw the outputs as broad estimates, to be adapted by experienced occupational hygienists.
What you need from your safety data sheets
| Input | Where on the SDS |
|---|---|
| Physical state (solid, liquid, gas) | Section 9 |
| Vapour pressure | Section 9 |
| Dust or particle characteristics | Section 9 |
| Uses and how the product is applied | Section 1.2 and the exposure scenario |
| Exposure controls (ventilation, containment) | Section 8 and the exposure scenario |
| Skin contact level | Not on the SDS: your own task description |
What NextSDS does with it
NextSDS does not calculate EASE. The model is obsolete, no longer distributed and its inhalation tree cannot be rebuilt from public sources. NextSDS uses EASE only as background to explain where ECETOC TRA values come from. For screening, NextSDS works with current models that use the same SDS data.
Countries
| Country | Role | Basis |
|---|---|---|
| Owner | Developed by HSE in the early 1990s; Windows version 2.0 produced by HSE in 1997 (Northage 2005, Ann Occup Hyg 49:99); used by HSE in risk assessment of new and existing chemicals (Tickner et al. 2005 abstract) | |
| Recommended | Historical, pre-REACH: named in the EU Technical Guidance Document 1996 and revised TGD 2003 for new and existing substances (Northage 2005; HERAG FS 01 p. 5). Under REACH only the basis of ECETOC TRA (ECHA R.14 v2.1 p. 20); not listed as a REACH tool |
Limitations
- Not transparent. Neither the structure nor the principles of EASE were published in the open literature (Tickner et al. 2005).
- Inhalation often too high. In 62% of 28 end points EASE was generally higher than about 4,000 measurements, and comparable in 30% (Cherrie and Hughson 2005).
- Skin estimates far too high. Creely et al. (2005) found “considerable overestimates” of skin exposure. For metals HERAG Fact Sheet 01 found overestimates by a factor of 35 to 550 and called the skin module “not suitable for regulatory risk assessment”.
- Built on problem areas. The data came from HSE enforcement visits in known problem areas, and EASE assumes tonne quantities are handled (ECETOC TR 93; ECHA R.14 v2.1).
- Weak on controls. Insufficient account of how well local exhaust ventilation works (ECETOC TR 93).
Key dates
| Date | Event |
|---|---|
| March 2005 | Annals of Occupational Hygiene publishes papers on the history and validation of EASE |
| 2003 | EU Technical Guidance Document revised; HSE evaluation report on EASE 2.0 |
| August 1997 | EASE for Windows 2.0 released by HSE with AIAI Edinburgh |
| 1996 | EASE included in the first EU Technical Guidance Document |
| Early 1990s | First MS-DOS version developed by HSE |
Frequently asked questions
Can I still use EASE?
No. It is no longer distributed and it is not a REACH tool. Use ECETOC TRA, its successor for REACH, or a higher tier model.
Why does EASE still matter?
ECETOC TRA worker estimates are modified EASE values (ECHA Guidance R.14 v2.1), and MEASE uses the EASE skin exposure classes. Older EU risk assessment reports also rely on EASE.
Which SDS data did EASE use?
The physical state and vapour pressure or dust characteristics (section 9), the way the product is used and the controls in place (sections 1.2 and 8 and the exposure scenario).
Is EASE conservative?
Mostly, but not always. Studies found it often higher than measurements, and its skin module much too high. ECETOC found some underestimates, mainly for dusty solids.
Related frameworks
- ECETOC TRA worker: described in ECHA Guidance R.14 as a modified version of EASE 2.0.
- MEASE 2: uses the EASE skin classes with measured values for metals.
- TREXMO: keeps EASE descriptors for translation between exposure models.
- ART: a later, higher tier tool that combines a model with measured data.
Official sources
- Tickner J et al., The development of the EASE model, Annals of Occupational Hygiene 49:103-110, 2005
- Northage C, EASEing into the future, Annals of Occupational Hygiene 49:99-101, HSE, 2005
- Cherrie JW and Hughson GW, The validity of the EASE expert system for inhalation exposures, Annals of Occupational Hygiene 49:125-134, 2005
- Creely KS et al., Evaluation and further development of EASE model 2.0, Annals of Occupational Hygiene 49:135-145, 2005
- HERAG Fact Sheet 01: occupational dermal exposure for metals, EBRC, August 2007
- ECHA guidance on information requirements and chemical safety assessment, ECHA, Chapter R.14 Occupational exposure estimation
This page is not legal advice; always check the official text.