TREXMO (TRanslation of EXposure MOdels)

A free Swiss web tool that runs the main REACH worker inhalation models side by side and translates one description of a task into the inputs of each model.

Exposure model Tier 2 (refined) In progress Last reviewed 28 November 2026

Quick answer

TREXMO lets you describe a work task once and get matching inputs and estimates in six REACH worker inhalation models, including ART, Stoffenmanager and ECETOC TRA. Use it to compare models and to make consistent input choices. It is not a model of its own: each result keeps the scope and limits of the model behind it.

What it is

TREXMO was published in 2016 by researchers in Lausanne, Geneva and at SECO, the Swiss State Secretariat for Economic Affairs (Savic et al. 2016). The current web tool is run by Unisante in Lausanne with SECO support. It holds these models:

Model Tier
ART 2
Stoffenmanager (published version 4.0 algorithm) 1.5
ECETOC TRA version 3 1
MEASE (metals) 1
EMKG-Expo-Tool (BAuA) 1
EASE 1

When a task was described in ART, TREXMO cut the number of possible outcomes in the other models by 1 to 4 orders of magnitude (Savic et al. 2016). In 2020 the same group published TREXMO+, a research model that combines ART, Stoffenmanager and ECETOC TRA estimates (Savic et al. 2020).

Does it apply to you?

TREXMO helps when:

  • You assess worker inhalation of vapours, mists or dusts and want to see how different REACH models compare.
  • You already work with one model (often ART) and want consistent inputs for the others.
  • You check an exposure scenario from a supplier against a second model.

TREXMO does not help when:

  • You need skin exposure: it covers inhalation only.
  • You need gases or fumes: only some of the models cover them (MEASE and EASE for gases, MEASE for fumes).
  • You want a new or better estimate than the models give: TREXMO adds no model of its own.

How it works

  1. Describe the task in one model, usually ART: product, activity, controls, room and duration.
  2. TREXMO translates these inputs into the matching inputs of the other models, using the published translation rules of Savic et al. 2016.
  3. Each model calculates its own estimate with its own method.
  4. You compare the results, keeping each model’s scope in mind.

Scope per model, as shown on the tool:

Model Dusts Abrasive solids Fumes Mists Vapours Gases
ART yes yes no yes yes no
Stoffenmanager yes yes no yes yes no
ECETOC TRA yes partly no partly yes no
MEASE yes partly yes partly yes yes
EMKG-Expo-Tool yes no no no yes no
EASE yes yes no no yes yes

What you need from your safety data sheets

Input Where on the SDS
Physical state and product type Section 9, section 1.2
Concentration of the substance in the product Section 3
Vapour pressure or boiling point Section 9
Dustiness (for powders) Section 9, rarely given
Engineering controls and ventilation Section 8.2
Exposure limit to compare the results with Section 8.1

Task details (activity, duration, room, amounts) are not on the SDS. You add them from the workplace.

What NextSDS does with it

NextSDS does not run TREXMO. NextSDS screens worker inhalation exposure with Tier 1 tools (ECETOC TRA worker and the EMKG-Expo-Tool). The TREXMO idea of describing a task once and deriving the inputs of several models guides how NextSDS plans to collect task information.

Countries

CountryRoleBasis
SwitzerlandOwnerDeveloped by Unisante (Lausanne) with the support of the Swiss State Secretariat for Economic Affairs SECO (tool footer); Savic et al. 2016 authors from IST Lausanne and SECO

No authority names TREXMO as a method. The models it runs have their own status, for example ART and ECETOC TRA in ECHA Guidance R.14.

Limitations

  • No new model: every estimate keeps the scope and bias of the model behind it.
  • Its Stoffenmanager follows the published version 4.0 algorithm and may differ from the current commercial Stoffenmanager (TREXMO website).
  • EASE is not referenced by ECHA (TREXMO website).
  • TREXMO+ predicts only the geometric mean, not the 90th percentile REACH needs, and was tested on small data sets (Savic et al. 2020). It is a research model, not a regulatory tool.
  • No licence or terms of use are published on the website.

Key dates

Date Event
29 June 2016 TREXMO published online (Savic et al. 2016)
2020 TREXMO+ research model published (Savic et al. 2020)
2026 Web tool run by Unisante with SECO support

Frequently asked questions

Is TREXMO accepted under REACH?

TREXMO itself has no formal status. Most of the models it runs, such as ART, ECETOC TRA, Stoffenmanager, MEASE and the EMKG-Expo-Tool, are described in ECHA Guidance R.14.

Is TREXMO free?

Yes. You register on the website and use it at no cost.

Will TREXMO give the same result as the original tools?

Not always. TREXMO implements the published algorithms; for example its Stoffenmanager follows version 4.0 and can differ from the current commercial version.

How do I cite results from TREXMO?

The website asks users to cite Savic et al. 2016.

Official sources

This page is not legal advice; always check the official text.

Key facts

TREXMO

Scope

Type
Exposure model
Tier
Platform for Tier 1 to Tier 2 models
Routes
Inhalation
Populations
Workers
Exposure forms
Vapour, mist, dust (depending on the model)

Status

Legal status
No formal status; the models it runs have their own status under REACH
Current version
Web tool at trexmo.unisante.ch (no version number shown)
Version date
29 June 2016
Licence type
Free to use
Licence terms
Web tool free after registration

Source

Official name
TREXMO (TRanslation of EXposure MOdels)
Owner
Unisante, Lausanne, with the University of Lausanne; supported by SECO

NextSDS

2,437 SDSs. None left to chase.

NextSDS collects the safety data sheets you receive and keeps them current, so the inputs for TREXMO and every other framework on this site are at hand.

Try NextSDS How it works