Quick answer
This model estimates how much welding fume a welder breathes over a shift, and how much reaches colleagues elsewhere in the room. You enter the welding wire (or the emission rate of the process), the arc time, the room and the extraction; you get a typical value and a high value (P95) in mg/m³ to compare with your limit. It covers total fume only: check chromium(VI), manganese and nickel separately.
What it is
A mass balance model published by Koivisto and co-workers in 2025 (open access, CC BY). The room is split into a small zone around the arc (near field, where the welder breathes) and the rest of the room (far field). Fume is released in the near field while the arc burns, mixes into the far field and leaves with the ventilation or the extraction. Uncertain inputs are varied over realistic ranges, so the result is a distribution, not one number.
Does it apply to you?
| Use it for | Do not use it for |
|---|---|
| Arc welding indoors (MIG/MAG shown in the paper, covered electrode in its validation) | Exposure to individual metals or gases on their own |
| Welding without extraction, with a fume extraction torch, or with an extraction arm that blows outside | Recirculating filters, downdraft tables, booths |
| Welder and bystanders in the same room | Very confined spaces |
How it works
- Emission. Emission factor of the wire (mg fume per g wire) times the wire used per minute; or the emission rate of the process from a fume data sheet or TRGS 528.
- Room. Fume enters the near field (1 to 7 m³), exchanges with the far field, and leaves with the general ventilation or the extraction. An extraction captures a share of the fume at the source.
- Uncertainty. Everything you do not enter is varied over the ranges published in the paper; 10 000 runs give the distribution.
- Result. 8 hour average for welder and bystander; above the limit at P95 means not compliant, below means adequately controlled (criteria of the paper).
What you need from your safety data sheets
| Input | Where |
|---|---|
| Wire type, fume emission rate | Section 8 or the fume data sheet of the wire (ISO 15011-4) |
| Limit value for welding fume | Section 8, or your national list |
| Feed rate, arc time, room, extraction | Your workplace, not the SDS |
What NextSDS does with it
NextSDS implemented the model from the paper and reproduced all its published simulation results. You can try it below. It is not yet part of the NextSDS product.
Countries
| Country | Role | Basis |
|---|---|---|
| International | Owner | Peer reviewed method, Koivisto et al. 2025, Open Research Europe 5:38 |
| Accepted | ECHA Guidance R.14 section R.14.5: Tier 2 assessment with any suitable, valid method | |
| Used | Emission groups and process emission rates from TRGS 528 (Ausgabe Februar 2020) used as optional input |
Limitations
- Total fume only; metals and gases need their own assessment.
- The air exchange around the welder and the capture of the extraction are rarely measured and drive the result.
- Tested against measurements without extraction only; with low ventilation the model tends to over estimate.
Key dates
- 2025-06-13: latest version of the Koivisto et al. paper.
- 2020-03-30: TRGS 528 (Ausgabe Februar 2020) published.
Frequently asked questions
Is a result below the limit enough for my risk assessment?
It shows the total fume is adequately controlled under the conditions you entered. Your risk assessment still needs the metals (for stainless steel especially chromium(VI)) and, where required, measurements.
What if I do not know the room ventilation?
Leave it empty: the model then uses the ranges from the paper (5 to 20 air changes per hour) and tells you which inputs it filled in.
Related frameworks
- IH MOD and the near field / far field models
- Verbetercheck Lasrook (Dutch metal sector)
- Lasrook assistent
Official sources
- Koivisto AJ, Eliat M, Jayjock M, Hussein T, Nicosia A. Quantifying relevant exposure determinants and conditions of use for welding emissions. Open Research Europe 5:38 (2025), doi:10.12688/openreseurope.19498.3.
- Extended data (simulation reports), Zenodo, doi:10.5281/zenodo.14744819.
- TRGS 528 Schweißtechnische Arbeiten, Ausgabe Februar 2020, GMBl 2020 S. 236-276, BAuA.