Quick answer
NanoSafer estimates how much nanomaterial a worker breathes in near the source and further away in the room, compares it with an exposure limit and gives a control level. Use it to screen nanopowder handling and processes with a known emission rate. It needs dustiness or an emission rate, the room size and the air exchange, and the tool is still labelled beta.
What it is
NanoSafer is a free web tool of the Danish National Research Centre for the Working Environment (NFA). Version 1.0 was developed with the Danish Technological Institute for the Danish industry and education work environment councils (Kristensen et al. 2010). Version 1.1beta was revised by NFA with support from the Danish Nanosafety Centre, and was further developed and tested in the EU project caLIBRAte (2016 to 2019). It is available in Danish and English after free registration.
Does it apply to you?
NanoSafer fits when you make or use manufactured nanomaterials such as nanoparticles, nanoflakes, nanofibres or nanotubes, and you:
- handle nanopowders and know (or can estimate) their dustiness in mg/kg;
- run a process that releases nanoparticles at a known or estimated rate in mg/min;
- want a first estimate and a control recommendation without measuring.
A material counts as nano relevant when its particles are 200 nm or smaller, or its specific surface area is 30 m²/g or more (NANoREG D3.08).
For a priority band without a room model, see Stoffenmanager Nano.
How it works
- Nano relevance: particle size or specific surface area is checked against the criteria above.
- Hazard score from 0.2 to 1.0, based on the hazard data of the material or its nearest analogue. A score of 1 means a high potential hazard.
- Reference limit: a nano specific or in-house exposure limit if you have one; otherwise the tool scales the official limit of the bulk material by the surface area of the nanomaterial.
- Emission rate: either a constant release rate, or for powder handling the dustiness times a handling energy factor (based on the free drop height) times the mass flow.
- Two box model: a near field box of 2.3 x 2.3 x 2.3 m around the source and the rest of the room as far field, calculated minute by minute with air exchange between the boxes.
- Exposure in the near and far field, for 15 minutes and 8 hours.
- Exposure score = exposure divided by the limit. Action is needed from 0.1; above 1 the exposure is critical.
- Control band: hazard and exposure scores give a control level and the protection efficacy needed, with a PDF report.
What you need from your safety data sheets
| Input | Where on the SDS |
|---|---|
| Particle size, shape, solubility and specific surface area | Section 9, or the technical data sheet |
| Hazard data of the material | Sections 2 and 11 |
| Exposure limit for respirable dust or the substance | Section 8.1 |
| Dustiness (mg/kg, EN 15051 or EN 17199) | Section 9, rarely given |
The process type, mass flow or emission rate, cycle times, room volume and air exchange come from the workplace. Hazard data for the nanoform itself are often missing from the SDS (NANoREG D3.08).
What NextSDS does with it
NextSDS has researched NanoSafer but does not calculate its results. NextSDS keeps the safety data sheets that hold the inputs listed above, so you can find them when you use the official tool.
Countries
| Country | Role | Basis |
|---|---|---|
| Owner | Developed and maintained by NFA (NRCWE), Copenhagen; v1.0 for the Danish industry and education work environment councils; v1.1 funded by the Danish Work Environment Research Fund and Danish Government (www.nanosafer.org) | |
| Used | DTU guidance 'Risk assessment of nanoparticles' (updated 7 Jan 2026): NanoSafer can be used as an aid to the preparation of the risk assessment; NFA slides Dec 2018 | |
| Used | Listed in the NanoReg2 Safe Innovation Approach toolbox hosted by RIVM (page of 8 Sep 2017, modified 2 Nov 2018); evaluated in EU FP7 NANoREG D3.08 and developed in H2020 caLIBRAte |
Limitations
- A 2016 comparison found that the outputs did not compare well with measured hazard and release data, and suggested adding factors for ventilation effectiveness and high process temperature (Sánchez Jiménez 2016).
- Different users gave very different scores for the same scenario, the widest spread of the nano tools tested (NANoREG D3.08).
- The tool is labelled beta; NFA says the algorithms may change.
- The model is simplified and in practice does not account for particle coagulation and deposition (NANoREG D3.08).
- Dustiness and nanoform hazard data are often not available from the supplier.
Key dates
| Date | Event |
|---|---|
| 2010 | NanoSafer 1.0 (NFA and the Danish Technological Institute) |
| 2013 | Version 1.1 presented at the NanOEH conference |
| 21 December 2016 | Quick Guide version 1.0 for 1.1beta |
| 2 May 2019 | Quick Guide version 1.01 |
| 2 October 2019 | Handling energy factors and precautionary exposure scaling revised |
| 19 May 2020 | Programming error in point source and leak scenarios corrected |
Frequently asked questions
Does NanoSafer give a concentration?
It calculates near field and far field concentrations of respirable aerosol internally. You see them as exposure scores and a control band.
Which exposure limit should I enter?
A nano specific or in-house limit if you have one, otherwise the official national limit for the bulk material (Quick Guide).
Is it validated?
Only weakly. Independent studies found poor agreement with measurements and a wide spread between users. Treat the result as a screening.
Does it cost anything?
No. The tool is free after registration.
Related frameworks
- Stoffenmanager Nano: nanomaterial risk banding, evaluated in the same NANoREG study
- Stoffenmanager: exposure model for conventional chemicals
- Advanced REACH Tool (ART): higher Tier exposure model
Official sources
- NanoSafer, NFA, version 1.1beta, read 28 November 2026
- NanoSafer 1.1beta Quick Guide, NFA, version 1.01, 2 May 2019
- NanoSafer tool, NanoReg2 Safe Innovation Approach toolbox, RIVM, modified 2 November 2018
- Risk assessment of nanoparticles, DTU, updated 7 January 2026
- NANoREG D3.08, Improved and validated occupational exposure models, NANoREG (EU FP7), version 2, 8 March 2017
This page is not legal advice; always check the official text.