Quick answer
RISKOFDERM estimates how much of a product lands on a worker’s hands and body during a task, per minute, based on measurements from an EU research project. It is the Tier 2 skin exposure model named in ECHA Guidance R.14, used when a first screen is not precise enough. It does not count the protection of gloves or clothing, is weak for powders and is not suitable for very volatile substances.
What it is
RISKOFDERM (Risk Assessment of Occupational Dermal Exposure to Chemicals) was an EU 5th Framework research project with scientists from 15 institutes in 10 European countries, coordinated by TNO in the Netherlands. The project measured skin exposure in industrial and professional settings. From these data Warren et al. (2006) built six statistical models, one per type of task, called Dermal Exposure Operation units (DEO units). The project also produced a separate risk assessment and risk management toolkit for small companies; this page covers the quantitative model.
Does it apply to you?
RISKOFDERM fits when you need a more precise estimate of skin exposure for a specific task, for example after ECETOC TRA flags a dermal risk. It covers industrial and professional workers handling liquids or solids in six types of task.
It is less suitable when:
- the substance is very volatile (above about 500 Pa vapour pressure);
- you need the dose under gloves or clothing (apply protection factors separately);
- your task or inputs fall outside the measured data;
- you need a full shift with several tasks combined.
For metals, MEASE uses measured skin exposure bands instead.
How it works
- Choose the DEO unit that matches the task:
| DEO unit | Example tasks |
|---|---|
| 1 Filling, mixing, loading | filling, loading, mixing and diluting, maintenance |
| 2 Wiping | wiping surfaces by hand |
| 3 Dispersion with hand-held tools | pouring, rolling, brushing |
| 4 Spraying | spraying |
| 5 Immersion | dipping objects, electroplating |
| 6 Mechanical treatment of solid objects | machining, grinding, sawing |
- Enter the task details for that unit, such as use rate of the product, type of contact, ventilation and distance to the source. The tool warns when inputs are outside the measured data.
- Get the median exposure rate for hands and/or body, in mg or µl of product per minute.
- Pick a percentile. With a geometric standard deviation the model gives any percentile. ECHA Guidance R.14 advises the 75th percentile when all inputs are conservative and the 90th percentile with less conservative inputs.
- Multiply by the task duration for the total exposure.
- Apply gloves or clothing separately, outside the model.
What you need from your safety data sheets
| Input | Where on the SDS |
|---|---|
| Type of product (liquid, powder, solid) | Section 9 |
| Viscosity | Section 9 |
| Vapour pressure (volatility) | Section 9 |
| Dustiness | Section 9 |
| Uses and type of task | Section 1.2 and the exposure scenario |
| Ventilation and protective measures | Section 8 and the exposure scenario |
| Use rate, contact type, duration | Not on the SDS: your own task description |
What NextSDS does with it
NextSDS has researched RISKOFDERM but does not calculate it yet. The model coefficients sit in the Warren et al. (2006) paper and the original TNO spreadsheet is no longer online. NextSDS plans it as a higher tier skin exposure step after its first tier dermal screening. The SDS data it needs (product type, viscosity, vapour pressure, uses and controls) are already read from your safety data sheets.
Countries
| Country | Role | Basis |
|---|---|---|
| Accepted | ECHA Guidance R.14 v2.1 (Nov 2012) section R.14.5.2 pp. 36 to 39 describes RISKOFDERM as a Tier 2 dermal model for REACH; section R.14.5 allows any suitable valid Tier 2 method | |
| Owner | Project coordinated by TNO Chemistry, Zeist (van Hemmen 2005, TTA 18(1):12); spreadsheet and guidance hosted on the TNO website (R.14 v2.1 footnote 11) |
Limitations
From ECHA Guidance R.14 v2.1 (section R.14.5.2):
- Not independently validated. “The validity of the model has not been established with independent data”; an early benchmark appeared “quite reasonable”.
- Potential exposure only. No protective effect of gloves or clothing.
- Limited data for powders.
- Not for very volatile substances. No data above about 500 Pa vapour pressure, so evaporation from the skin is not covered.
- Only hands or body. No split into smaller skin areas, and not every DEO unit has both a hands and a body model.
- Inputs may be hard to find, such as use rate and airflow direction.
- No full shift combination of tasks in the spreadsheet.
- Metals. Bagging, mixing and unloading of metals are not addressed (HERAG Fact Sheet 01).
Key dates
| Date | Event |
|---|---|
| November 2012 | ECHA Guidance R.14 v2.1 describes RISKOFDERM and the spreadsheet vs 2.1t |
| March to July 2006 | Model paper (Warren et al.) and default values paper (Marquart et al.) published |
| 2005 | Toolkit paper by van Hemmen |
| 2004 | Field work published in the Annals of Occupational Hygiene |
Frequently asked questions
Does RISKOFDERM tell me the dose on the skin?
No. It estimates potential exposure, on the skin plus gloves and clothing. Apply protection factors separately.
Which percentile should I use?
ECHA Guidance R.14 advises the 75th percentile when all inputs are conservative and the 90th percentile with typical inputs.
Can I use it for solvents?
Not for very volatile substances above about 500 Pa vapour pressure, because the measured data do not cover them.
Which SDS data does RISKOFDERM use?
The product type, viscosity, vapour pressure and dustiness (section 9), the uses (section 1.2 and the exposure scenario) and the controls (section 8). Use rate, contact type and duration come from your own task.
Related frameworks
- ECETOC TRA worker: Tier 1 screening; RISKOFDERM is a common next tier for skin exposure.
- EASE 2.0: an older general model; RISKOFDERM based approaches are preferred over it (Marquart et al. 2006).
- MEASE 2: skin exposure for metals with measured bands.
- Stoffenmanager: its dermal module builds on the RISKOFDERM toolkit.
Official sources
- Warren ND et al., Task-based dermal exposure models for regulatory risk assessment, Annals of Occupational Hygiene 50(5):491-503, 2006
- Marquart H et al., Default values for assessment of potential dermal exposure of the hands to industrial chemicals, Annals of Occupational Hygiene 50(5):469-489, 2006
- van Hemmen JJ, RISKOFDERM: risk assessment of occupational dermal exposure to chemicals, TNO, 2005
- ECHA guidance on information requirements and chemical safety assessment, ECHA, Chapter R.14 Occupational exposure estimation
This page is not legal advice; always check the official text.