Generic and refined 2-box spray model

Simple screening model from Fraunhofer ITEM and BAuA that estimates the average air concentration of a substance sprayed indoors from six easy inputs.

Exposure model Tier 1 (screening) Complete Last reviewed 28 November 2026

Quick answer

The 2-box spray model is a quick, conservative check of how much of a sprayed substance a worker breathes in during indoor spraying. It needs only the spray rate, the share of the substance in the liquid, the room size, the ventilation and the spraying and exposure times. It almost never underestimates, but it often overestimates surface spraying a lot, so treat a high result as a reason to look closer, not as a final answer.

What it is

Researchers from Fraunhofer ITEM and BAuA published the model in February 2024, as part of BAuA research project F2492. It splits the air into two boxes: a personal zone around the worker, where the spray first mixes, and the rest of the room, which is ventilated. The generic version leaves out droplet settling and evaporation, which keeps it simple and conservative. A refined version adds correction factors for these effects, and a third version uses measured release fractions for specific equipment. The authors call it a simple tier 1 approach and evaluated it against 78 workplace measurements.

Does it apply to you?

The model fits when:

  • your workers spray a liquid indoors, either into the room (fogging, room disinfection) or onto surfaces;
  • the substance of concern is non-volatile and sits in water or a solvent, for example a disinfectant active substance;
  • you know roughly the spray rate, the spraying time, the room size and the ventilation.

Use another tool when:

  • the spraying is outdoors: wind is not modelled;
  • the substance itself is volatile: the model could in principle be used, but it was not evaluated for volatile substances;
  • you need skin exposure: the model covers inhalation only;
  • you have detailed equipment data and need a refined estimate: SprayExpo is the higher tier.

How it works

  1. Personal zone: during spraying, the spray mixes into a personal zone of 10 m³ that is refreshed every 0.1 minute, an air flow of 100 m³ per minute that reflects the movement of the worker and the air pulled into the spray.
  2. Room: the spray then spreads into the room, where the concentration builds up during spraying and falls with the ventilation afterwards.
  3. Average: the model adds the average concentrations of both zones over your exposure time to give one time weighted average in mg/m³.
  4. Refined version (optional): correction factors from the paper’s tables lower the result, depending on room or surface spraying, ventilation, the vapour pressure of the solvent (three classes) and fine or coarse droplets. For surface spraying, 30 percent of the spray is assumed to stay airborne.
  5. Release fraction version (optional): for flat fan and hollow cone nozzles 1 percent of the spray becomes airborne, for handheld pump sprays 10 percent.
  6. When in doubt: if the type of application or equipment is unclear, calculate as room spraying, which gives the highest estimate.

What you need from your safety data sheets

Input Where on the SDS
Use as a spray product Section 1 (1.2 identified uses)
Share of the substance in the sprayed liquid Section 3 (correct for any dilution before use)
Vapour pressure of the solvent (refined version) Section 9
Spray rate, spraying and exposure time, room size, ventilation Not on the SDS: workplace and equipment data

What NextSDS does with it

NextSDS has implemented the generic 2-box spray model in its calculation engine and tested it against the published equations. It is not yet part of the standard product assessment, and the refined and release fraction versions are planned. NextSDS reads the composition and the vapour pressure from your safety data sheets, which are the SDS inputs the model needs.

Countries

CountryRoleBasis
GermanyOwnerDeveloped by Fraunhofer ITEM with BAuA, funded by BAuA project F2492 (Hahn et al. 2024, Funding statement)

No other country status was found.

Limitations

  • The generic version overestimated the measurement by more than 100 times in about 60 percent of the 78 scenarios; for room spraying it was usually at most 10 times the measurement (Hahn et al. 2024).
  • The generic and refined versions did not underestimate in any of the four data sets; the release fraction version underestimated 30.8 percent of one data set (Hahn et al. 2024, Table 3).
  • It was evaluated with non-volatile substances only.
  • It is for indoor spraying only.
  • The fixed personal air flow of 100 m³ per minute is higher than literature values for stationary sources (0.24 to 30 m³ per minute), which makes the near zone estimate conservative (Hahn et al. 2024).

Key dates

  1. The generic, refined and release fraction versions are published in Frontiers in Public Health.
  2. A review by the same group identifies the need for simple spray models (Hahn et al. 2021).

Frequently asked questions

How reliable is the 2-box spray model?

It is built to be on the safe side. In the published evaluation it never underestimated with the generic or refined version, but it often overestimated surface spraying by more than 100 times.

Should I calculate room spraying or surface spraying?

Room spraying if you are unsure: it gives the highest estimate. Use surface spraying only when the equipment clearly sprays onto a surface.

Can I use it for solvents?

In principle all sprayed liquid becomes airborne, so the result is a reasonable worst case, but the model was not evaluated for volatile substances.

Which SDS data does the model use?

The share of the substance from section 3, and for the refined version the vapour pressure of the solvent from section 9. Spray rate, times and room data come from your workplace.

  • SprayExpo: the higher tier spray model from the same research group.
  • ConsExpo: its authors present the 2-box model as an extension of the ConsExpo instant release spray model.
  • ART: an empirical workplace model with a branch for spraying.
  • Near field far field model: the general two zone model used in industrial hygiene.

Official sources

This page is not legal advice; always check the official text.

Key facts

2-box spray model

Scope

Type
Exposure model
Tier
1 (screening)
Routes
Inhalation
Populations
Workers
Exposure forms
Spray aerosol of non-volatile substances in a liquid, indoors

Status

Legal status
Published research method; no formal regulatory status
Current version
Hahn et al. 2024 (generic, refined and release fraction versions)
Version date
9 February 2024
Licence type
Open licence
Licence terms
Open access article (CC BY)

Source

Official name
Generic and refined 2-box spray model (Hahn et al. 2024)
Owner
Fraunhofer ITEM and BAuA (Germany)
Official site
doi.org

Try it

Calculate 2-box spray model with your own inputs

Loading the calculation...

NextSDS

2,437 SDSs. None left to chase.

NextSDS collects the safety data sheets you receive and keeps them current, so the inputs for 2-box spray model and every other framework on this site are at hand.

Try NextSDS How it works