CB Nanotool (Control Banding Nanotool)

Published scoring tool from LLNL that turns what you know about a nanomaterial and the task into a risk level RL1 to RL4 with the matching control, even when most data are unknown.

Control banding Tier 0 (banding) Complete Last reviewed 28 November 2026

Quick answer

The CB Nanotool tells you which control a task with engineered nanomaterials needs: general ventilation (RL1), a fume hood or local exhaust (RL2), containment (RL3) or specialist advice (RL4). You rate the nanomaterial, its bulk material and the task; every question accepts “Unknown”. If you know nothing, the answer is containment. It gives no exposure concentration and was built for small scale laboratory work.

What it is

A control banding tool published in 2008 by Samuel Paik, David Zalk (Lawrence Livermore National Laboratory) and Paul Swuste (Delft University of Technology). It adds up points for how harmful the nanomaterial may be (severity) and how likely workers are to be exposed (probability), and reads the risk level from a 4 by 4 matrix. The authors tested it on five operations at two US research laboratories and in 2009 on 27 more, and proposed updated weights in 2009.

Does it apply to you?

Use it when your staff handle engineered nanoparticles (particles with two or three dimensions below 100 nm) in research, pilot or other small scale work, as powders, suspensions or sprays. It is useful when the safety data sheet says little about the nano form, because unknown answers are allowed. For large scale production the authors say the amount and other task ranges may need to change and each process step needs its own assessment. For a concentration estimate, use an exposure model instead.

How it works

  1. Severity (0 to 100 points). Nanomaterial, up to 70 points: surface reactivity, particle shape, particle diameter, solubility, and whether it causes cancer, harms reproduction, is mutagenic or harms the skin. Bulk material, up to 30 points: the lowest limit value (OEL) and the same four hazards.
  2. Probability (0 to 100 points). Amount of nanomaterial per task (up to 25), dustiness or mistiness (up to 30), number of employees, how often and how long (up to 15 each).
  3. Unknown answers count as 75% of the highest points of that question.
  4. Bands. 0 to 25, 26 to 50, 51 to 75 and 76 to 100 give low, medium, high and very high severity, and extremely unlikely, less likely, likely and probable exposure. If the task makes no dust or mist at all, exposure is extremely unlikely whatever the other answers.
  5. Risk level from the matrix:
Severity \ Probability Extremely unlikely Less likely Likely Probable
Very high RL3 RL3 RL4 RL4
High RL2 RL2 RL3 RL4
Medium RL1 RL1 RL2 RL3
Low RL1 RL1 RL1 RL2

The 2009 revision adds “causes asthma” for both the nanomaterial and the bulk material, lowers the weight of the other toxic effects so the totals stay the same, and uses new limit value bands. The matrix and controls did not change.

What you need from your safety data sheets

Input Where on the SDS
Particle size, shape and solubility of the nano form Section 9 (often missing: answer Unknown)
Cancer, reproduction, mutagenicity, skin hazard of the nano form Section 11 (rarely nano specific)
Limit value of the bulk material Section 8
Hazards of the bulk material Sections 2 and 11
Physical form (powder, suspension) for dustiness Section 9
Amount, number of employees, frequency and duration Not on the SDS: from the task

What NextSDS does with it

NextSDS has rebuilt the published points scheme in its research code and checked it against all five worked examples of the 2008 paper (same scores, bands and risk levels) and the 27 band combinations of the 2009 paper. You can try both versions in the “Try it” section of this page. It is not part of the NextSDS product yet.

Countries

CountryRoleBasis
United StatesOwnerDeveloped at LLNL (US Department of Energy), Paik et al. 2008
United StatesUsedRequired risk assessment approach for nanomaterial work at LLNL (Zalk et al. 2009)

Limitations

  • No exposure concentration; the weights are expert choices of the authors.
  • Most nano specific questions cannot be answered from a typical SDS, so results often end at RL3.
  • Built for small scale research work; all amounts above 100 mg score the same.
  • In the authors’ evaluation the tool was equal to or stricter than the expert’s choice in 24 of 27 tasks.
  • No official software is published; the authors used a spreadsheet.

Key dates

  1. Evaluation with 27 more tasks and revised weights (Journal of Nanoparticle Research 11:1685-1704).
  2. Pilot tool published (Annals of Occupational Hygiene 52:419-428).

Frequently asked questions

What if I know nothing about the nanomaterial?

Answer Unknown everywhere. Severity and probability both end at 75 points, which gives RL3: containment. Each fact you find can lower the result.

When can I answer “None” for dustiness?

Only when the task makes no dust or mist at all, for example nanotubes fixed on a substrate or a liquid suspension that is not stirred or sprayed. The tool then treats exposure as extremely unlikely.

Which version should I use?

The 2008 version is fully published with worked examples. The 2009 version is the authors’ latest weighting; some of its points per answer follow the tool’s general rule rather than a printed table.

  • Stoffenmanager Nano: risk priority banding for manufactured nanomaterials
  • NanoSafer: Danish nanomaterial control banding with exposure scenarios
  • COSHH Essentials: the classic control banding matrix the CB Nanotool is based on

Official sources

This page is not legal advice; always check the official text.

Key facts

CB Nanotool

Scope

Type
Control banding
Tier
0 (banding)
Routes
Inhalation, dermal
Populations
Workers
Exposure forms
Engineered nanomaterials as dust or mist

Status

Legal status
No regulatory status; required approach for nanomaterial work at LLNL
Current version
Pilot 2008, revision proposed 2009
Version date
27 June 2009
Licence type
Public method
Licence terms
Published method in peer reviewed papers; no software licence

Source

Official name
Control Banding Nanotool
Owner
Lawrence Livermore National Laboratory (US); Paik, Zalk and Swuste
Official site
osti.gov

Try it

Calculate CB Nanotool with your own inputs

Loading the calculation...

NextSDS

2,437 SDSs. None left to chase.

NextSDS collects the safety data sheets you receive and keeps them current, so the inputs for CB Nanotool and every other framework on this site are at hand.

Try NextSDS How it works